Image from Google Jackets

Failure of a new 8-in pipeline from Group Gathering Station to Central Tank Farm

By: Publication details: mayo 2011Description: 4 p. ; 50-53 In: Materials Performance 50Summary: Transcripción del resumen del autor. An 8-in (203-mm) oil dispatch pipeline failed from internal corrosion withing eight months of commissioning. The premature failure is attributed to extremely high microbe content, significant quantity of volatile fatty acids, underdeposit pitting/crevice corrosion during stagnant flow, and the absence of pigging. Recommended chemical treatment and pigging practices have been implemented
Item type: Artículo de Revista
Holdings
Current library Status Barcode
Biblioteca Alejandro Angel Bulgheroni Not for loan 200053858

Transcripción del resumen del autor. An 8-in (203-mm) oil dispatch pipeline failed from internal corrosion withing eight months of commissioning. The premature failure is attributed to extremely high microbe content, significant quantity of volatile fatty acids, underdeposit pitting/crevice corrosion during stagnant flow, and the absence of pigging. Recommended chemical treatment and pigging practices have been implemented