Corrosion rate model for 8% Chromium cold-work tool steels in tannic acid
Publication details: feb. 2011Description: 5 p. ; 025006 In: Corrosion 67Summary: Transcripción del resumen del autor. Different cold-work tool steels have been treated with different heat treatments. The remaining Cr content within the matrix was calculated using thermodynamic and phase diagram calculations (for multi-component systems [TPC]). Corrosion tests were performed in tannic acid, and the corrosion rate for these materials was investigated. A logarithmic two-parameter corrosion rate model with heat treatment as constant parameter could be found with a 98.9% correlation coefficient. It is shown that, considering corrosion rate, there exists a heat treatment parameter that is as important as the Cr matrix content.| Current library | Status | Barcode | |
|---|---|---|---|
| Biblioteca Alejandro Angel Bulgheroni | Not for loan | 200051476 |
Transcripción del resumen del autor. Different cold-work tool steels have been treated with different heat treatments. The remaining Cr content within the matrix was calculated using thermodynamic and phase diagram calculations (for multi-component systems [TPC]). Corrosion tests were performed in tannic acid, and the corrosion rate for these materials was investigated. A logarithmic two-parameter corrosion rate model with heat treatment as constant parameter could be found with a 98.9% correlation coefficient. It is shown that, considering corrosion rate, there exists a heat treatment parameter that is as important as the Cr matrix content.