Optimal design of multi-stage natural gas compression with inter-and after - coolers using the mollier type charts

By: Publication details: Instituto Argentino del Petróleo y del Gas, IAPGDescription: 7 pSubject(s): DDC classification:
  • CD I116 43 0014775
Online resources: Summary: Fundamental operational equations required for design of multi-stage compressor stations equipped with inter- and after-coolers are reviewed. Applications are demonstrated for optimal design of typical compressor stations. Numerical examples are presented to illustrate the application of the theory and methodology for effective design of the compressor stations using the Mollier-type charts.
Item type: Congresos (trabajos presentados)
Holdings
Current library Call number Status Barcode
Colección Digital IAPG CD I116 43 0014775 (Browse shelf(Opens below)) Not for loan 200040515

Fundamental operational equations required for design of multi-stage compressor stations equipped with inter- and after-coolers are reviewed. Applications are demonstrated for optimal design of typical compressor stations. Numerical examples are presented to illustrate the application of the theory and methodology for effective design of the compressor stations using the Mollier-type charts.