Use of octadecylamine for shutdown protection at power plants

Publication details: ene. 2008Description: 5 p. ; 58-62 In: Materials Performance 47Summary: Shutdown protection for power plants was effectively carried out using octadecylamine (ODA). During ODA treatment, there was no great change in PH and water and vapor conductivity. After treatment, economizer, water wall, and superheater tubes showed black or dark grey inner surface morphologies. Impedance spectroscopy indicated that the corrosion resistance of ODA-treated tubes was higher than those without ODA treatment.
Item type: Artículo de Revista
Holdings
Current library Status Barcode
Biblioteca Alejandro Angel Bulgheroni Not for loan 200042079

Shutdown protection for power plants was effectively carried out using octadecylamine (ODA). During ODA treatment, there was no great change in PH and water and vapor conductivity. After treatment, economizer, water wall, and superheater tubes showed black or dark grey inner surface morphologies. Impedance spectroscopy indicated that the corrosion resistance of ODA-treated tubes was higher than those without ODA treatment.