| Resumen | Shutdown protection for power plants was effectively carried out using octadecylamine (ODA). During ODA treatment, there was no great change in PH and water and vapor conductivity. After treatment, economizer, water wall, and superheater tubes showed black or dark grey inner surface morphologies. Impedance spectroscopy indicated that the corrosion resistance of ODA-treated tubes was higher than those without ODA treatment. |
| 581 ## - ESTADO DE COLECCIÓN | |
| Estado de colección | 1 |
| 773 0# - CORRECCIÓN | |
| Título | Materials Performance |
| Partes relacionadas | 47 |
| 942 ## - DESC. DE MATERIAL | |
| Tipo de item KOHA | Artículo de Revista |
| Biblioteca propietaria | Biblioteca actual | Fecha de adquisición | Inventario | Total de préstamos | Inventario | Fecha de carga | Tipo de item KOHA |
|---|---|---|---|---|---|---|---|
| Biblioteca Alejandro Angel Bulgheroni | Biblioteca Alejandro Angel Bulgheroni | 05/03/2026 | 200042079 | 200042079 | 05/03/2026 | Artículo de Revista |