Image from Google Jackets

Lightweight high temperature test furnace 21st century technology

By: Contributor(s): Description: 14 pDDC classification:
  • CD I249 1 0013788
In: Summary: Transcripción del abstract original del autor: New high-temperature lightweight furnace design offers potential energy savings, thus reducing emissions and costs, and improves product quality. Gasunie Research 12 m3 test furnace: ; 36% less heat needed to heat up the furnace ; first tests shown that 18% of flue gas heat loss saved through pulse/pause firing ; reduced carbon dioxide and gaseous hydrogen fluorides (HF) emissions ; improved temperature homogeneity in product batch enables higher throughput ; new dust-free combination of Refractory Ceramic Fibres (RCFs) have been tested successfully up to 1250 °C ; new high-temperature vitreous wool (RCFs) with high solubility in body fluids and hence no hazard classification has been successfully tested ; furnace control system developed and tested with good results, based on a standard industrial PLC, within stringent gas safety requirements.
Item type: Congresos (trabajos presentados)
Holdings
Current library Call number Status Barcode
Biblioteca Alejandro Angel Bulgheroni CD I249 1 0013788 (Browse shelf(Opens below)) Not for loan 200025596

Disponible en CD en formato PDF

Transcripción del abstract original del autor: New high-temperature lightweight furnace design offers potential energy savings, thus reducing emissions and costs, and improves product quality. Gasunie Research 12 m3 test furnace: ; 36% less heat needed to heat up the furnace ; first tests shown that 18% of flue gas heat loss saved through pulse/pause firing ; reduced carbon dioxide and gaseous hydrogen fluorides (HF) emissions ; improved temperature homogeneity in product batch enables higher throughput ; new dust-free combination of Refractory Ceramic Fibres (RCFs) have been tested successfully up to 1250 °C ; new high-temperature vitreous wool (RCFs) with high solubility in body fluids and hence no hazard classification has been successfully tested ; furnace control system developed and tested with good results, based on a standard industrial PLC, within stringent gas safety requirements.



Instituto Argentino del Petróleo y del Gas
Maipú 639 (C1006ACG) – Buenos Aires – Argentina
Tel: (54 11) 5277 IAPG (4274)
Lu - Vie 11 a 17 hs
Mail: biblio@iapg.org.ar


Copyright © 2026, Instituto Argentino del Petróleo y del Gas, todos los derechos reservados.

Protección de datos personales