Lightweight high temperature test furnace 21st century technology
Description: 14 pDDC classification:- CD I249 1 0013788
| Current library | Call number | Status | Barcode | |
|---|---|---|---|---|
| Biblioteca Alejandro Angel Bulgheroni | CD I249 1 0013788 (Browse shelf(Opens below)) | Not for loan | 200025596 |
Disponible en CD en formato PDF
Transcripción del abstract original del autor: New high-temperature lightweight furnace design offers potential energy savings, thus reducing emissions and costs, and improves product quality. Gasunie Research 12 m3 test furnace: ; 36% less heat needed to heat up the furnace ; first tests shown that 18% of flue gas heat loss saved through pulse/pause firing ; reduced carbon dioxide and gaseous hydrogen fluorides (HF) emissions ; improved temperature homogeneity in product batch enables higher throughput ; new dust-free combination of Refractory Ceramic Fibres (RCFs) have been tested successfully up to 1250 °C ; new high-temperature vitreous wool (RCFs) with high solubility in body fluids and hence no hazard classification has been successfully tested ; furnace control system developed and tested with good results, based on a standard industrial PLC, within stringent gas safety requirements.