000 01870nab a2200241 4500
005 20260520001112.0
008 260224s2015 xxu ing
041 _aInglés
245 0 0 _aIgnition of Mulch Beds Exposed to Continuous Wind-Driven Firebrand Showers
260 _a
_b
_cjul. 2015
270 _a14/09/2015 ; 14/09/2015
300 _a17 p. ; 905-922
520 _aTranscripción del resúmen realizada por el autor: A series of experiments were conducted to examine ignition of mulch beds to continuous, wind-driven firebrand showers. Shredded hardwood mulch, fitted in beds 1.2 m by 1.2 m with a thickness of 51 mm, was attached to a non-combustible reentrant corner assembly. The mulch/reentrant corner assembly was then exposed to continuous, wind-driven firebrand bombardment generated by the NIST full-scale Continuous Feed Firebrand Generator installed in the Fire Research Wind Tunnel Facility at the Building Research Institute in Japan. These experiments have determined ignition behavior of mulch beds installed in realistic building configurations under wind-driven firebrand showers. Experiments were performed by varying the wind speed and moisture content (MC) of the mulch beds. It was observed that continuous application of small wind-driven firebrands, with sizes similar to those observed in actual wildland–urban interface fires in California and Texas, resulted in flaming ignition of mulch beds held at MC up to 83% under wind speeds of 8 m/s. The accumulation of firebrands was a key factor to produce ignition.
581 _a4
773 0 _tFire Technology
_g51
942 _cARTICULO
100 1 _aSuzuki, Sayaka
_954823
100 1 _aManzello, Samuel L.
_942650
100 1 _aKagiya, Koji
_954834
100 1 _aSuziki, Junichi
_954835
100 1 _aHayashi, Yoshihiko
_954836
999 _c189189