| 000 | 01546nab a2200193 4500 | ||
|---|---|---|---|
| 005 | 20260520002038.0 | ||
| 008 | 260224s2013 xxu ing | ||
| 041 | _aInglés | ||
| 245 | 0 | 0 | _aTest of SAGD Flow-Distribution-Control Liner System in the Surmont Field, Alberta, Canada |
| 260 |
_a _b _cmar. 2013 |
||
| 270 | _a03/06/2013 ; 03/06/2013 | ||
| 300 | _a5 p. ; 95-100 | ||
| 520 | _aTranscripción del resumen del autor. The Surmont Well Pair 102-06 started steam-assisted-gravity drainage (SAGD) operation in April 2009 with flow-distribution control (FDC) built into the horizontal liners for both the injection and the production wells. After preheat steam circulation, this liner system has allowed operation without a toe tubing string in either completion and has delivered superior steam-chamber development and overall performance. The design also allowed reducing the liner and casing size for the injection well. Future SAGD-well design may benefit by further reduction in liner and casing sizes for both the injector and producer, which could allow longer completions by reducing liner drag and increasing directional-drilling flexibility. Ultimately, these SAGD-well design changes could increase the amount of reservoir developed per well and per well pad, using longer wells and more wells per pad while achieving superior SAGD performance. | ||
| 581 | _a2 | ||
| 773 | 0 |
_tJournal of Canadian Petroleum Technology _g52 |
|
| 942 | _cARTICULO | ||
| 100 | 1 |
_aStalder, John L. _953294 |
|
| 999 |
_c187745 _d187745 |
||