000 01546nab a2200193 4500
005 20260520002038.0
008 260224s2013 xxu ing
041 _aInglés
245 0 0 _aTest of SAGD Flow-Distribution-Control Liner System in the Surmont Field, Alberta, Canada
260 _a
_b
_cmar. 2013
270 _a03/06/2013 ; 03/06/2013
300 _a5 p. ; 95-100
520 _aTranscripción del resumen del autor. The Surmont Well Pair 102-06 started steam-assisted-gravity drainage (SAGD) operation in April 2009 with flow-distribution control (FDC) built into the horizontal liners for both the injection and the production wells. After preheat steam circulation, this liner system has allowed operation without a toe tubing string in either completion and has delivered superior steam-chamber development and overall performance. The design also allowed reducing the liner and casing size for the injection well. Future SAGD-well design may benefit by further reduction in liner and casing sizes for both the injector and producer, which could allow longer completions by reducing liner drag and increasing directional-drilling flexibility. Ultimately, these SAGD-well design changes could increase the amount of reservoir developed per well and per well pad, using longer wells and more wells per pad while achieving superior SAGD performance.
581 _a2
773 0 _tJournal of Canadian Petroleum Technology
_g52
942 _cARTICULO
100 1 _aStalder, John L.
_953294
999 _c187745
_d187745