000 00912nab a2200193 4500
005 20260520003047.0
008 260224s2008 xxu
245 0 0 _aStress cracking of stainless steel safety gate valve stem
260 _a
_b
_cfeb. 2008
270 _a01/08/2011 ; 01/08/2011
300 _a4 p. ; 64-67
520 _aTranscripción del resumen del autor. This study investigated the failure of a 15-5 PH (UNS S15500) precipitation-hardened stainless steel stem when installed in a 5 1/8in. (130-mm) hydraulic surface safety gate valve working in a sour gas environment. The results indicate that the fracture failure was caused by sulfide stress cracking, which progressed transgranularly in the martensitic matrix.
581 _a2
773 0 _tMaterials Performance
_g47
942 _cARTICULO
100 1 _aMostofi, J.
_951114
100 1 _aZamanian, M.
_951115
999 _c184723