000 02869nab a2200205 4500
005 20260522180556.0
008 260224s2010 xxu
100 1 _aCarles, P.
_946739
100 1 _aBachaud, P.
_946740
100 1 _aLasseur, E.
_946741
245 0 0 _aConfining properties of carbonated dogger caprocks (Parisian Basin) for CO2 storage purpose
260 _cmayo/jun. 2010
270 _a31/08/2010 ; 31/08/2010
300 _a12 p. ; 457-468
520 _aTranscripción del resumen del autor. The Géocarbone-Intégrité project, funded by ANR (Agence Nationale de la Recherche) from 2006 to 2008, has the overall objective of gaining knowledge and technology to predict storage integrity and safety for long term geological CO2 sequestration. The aim of this study (Sect. 1 and 2 of the project) is to evaluate the sealing capacities of the carbonated Dogger caprocks located on top of the reservoirs where CO2 could be injected for storage purposes in the Parisian Basin. A petrographic analysis is done on 3 different cores from geological formations of the "Comblanchien and Dalle Nacrée" tight carbonates facies. At the same time, a petrophysical study of these facies is performed. Porosity, pore size distribution and permeability are determined using special devices adapted to low permeability and tight rocks (< 10 microDarcy). Permeabilities are measured with nitrogen, helium and brine under confining pressure using unsteady-state and steady-state methods. Porosities are low and vary from 2 to 9%, depending on the facies, and single-phase permeabilities vary from 0.3 to 20 microDarcy. Using different techniques of porosity and permeability measurement allows evaluation of the uncertainties. The sealing efficiency of a caprock towards CO2 is primarily controlled by the threshold capillary pressure at in situ conditions. This threshold pressure is first estimated by mercury injection (HPMI). It is also directly measured on core samples at in situ conditions with Nitrogen (N2) and Carbon dioxide (CO2) (to see the effect of CO2 compared to a neutral gas on the threshold pressure). Two different techniques, described in detail in this article, are used: the dynamic method and the pressure step method. For the CO2/brine system, measured threshold capillary pressures vary from 0.4 bar to 22 bar, depending on the facies. The Pth values, even for the tighter facies (CH106), are probably too low to exclude penetration of CO2 into the caprock. This however does not rule out storage of CO2, as long as it can be proved that the permeability of the caprock is low enough and its thickness large enough to limit the extent of this penetration even though overpressure is maintained for a long period.
581 _a3
773 0 _tOil and Gas Science and Technology
_g65
942 _cARTICULO
_2ddc
999 _c176581
_d176581