| 000 | 00939nab a2200205 4500 | ||
|---|---|---|---|
| 005 | 20260520002918.0 | ||
| 008 | 260224s2008 xxu | ||
| 245 | 0 | 0 | _aTesting corrosion rates on steel piping in geothermal district heating |
| 260 |
_a _b _cmayo 2008 |
||
| 270 | _a09/08/2010 ; 09/08/2010 | ||
| 300 | _a4 p. ; 56-59 | ||
| 520 | _aTranscripción del resumen del autor. The St-37 carbon steel piping in a geothermal heating system experienced increasing corrosion leaks. Tests with pipe steel coupons showed that while uniform corrosion rates were low, pitting rates were high. Sulfate-reducing bacteria were the main cause. Changes in fluid velocities and the addition of a bacteriacide were recommended. | ||
| 581 | _a5 | ||
| 773 | 0 |
_tMaterials Performance _g47 |
|
| 942 | _cARTICULO | ||
| 100 | 1 |
_aInce , Umut _946303 |
|
| 100 | 1 |
_aToksoy, Macit _946304 |
|
| 100 | 1 |
_aGuden, Mustafa _946305 |
|
| 999 |
_c175865 _d175865 |
||