000 01050nab a2200205 4500
005 20260520002845.0
008 260224s2009 xxu
245 0 0 _aMIC failure of type 316L seawater pipeline
260 _a
_b
_cene. 2009
270 _a27/01/2011 ; 27/01/2011
300 _a6 p. ; 64-69
520 _aTranscripción del resumen del autor. Type 316L stainless steel (SS) (UNS S31600) pipeline carrying seawater suffered pitting and leakage within a few years of installation. Visual examination revealed penetrations and shallow pits. Electron probe microanalysis results indicated a decrease in chromium concentration withing the pit and in the iron concentration at the pit periphery. Microbial investigation confirmed the presence of sulfate- reducing bacteria and chromium-, manganese-, and iron-oxidizing bacteria
581 _a1
773 0 _tMaterials Performance
_g48
942 _cARTICULO
100 1 _aAbraham, Geogy J.
_944341
100 1 _aKain, V.
_943536
100 1 _aDey, G.K.
_944342
999 _c173004