245 0 0 _aLDA and PIV characterization of the flow in a hydrocyclone without an air-core
260 _a
_b
_cfeb. 2010
270 _a17/06/2010 ; 17/06/2010
300 _a9 p. ; 168-176
520 _aTranscripción del resumen del autor. The three-dimensional flow in a hydrocyclone especially developed for application in the petroleum industry has been investigated through the LDA and PIV techniques for one experimental condition. In the present physical simulation, the hydrocyclone is set to operate without an air-core. The tangential (V ) and axial (Vz) mean velocity profiles are analyzed through both measuring techniques. Radial (Vr) mean velocity profiles are only accounted for through PIV. The exponent n in the tangential velocity equation, V rn = C, was determined to be about 0.61. For the radial profile, Vrrm = - D, m was found to be 1.59. The rms-values of two-velocity components — tangential and axial — were evaluated via LDA. Turbulence in the axial direction is observed to be slightly higher than turbulence in the tangential direction. Approaching the axis of symmetry of the cyclone, however, this trend is reversed. The fluctuations in the tangential direction are found to be at least twice higher than the axial fluctuations.
581 _a3-4
773 0 _tJournal of Petroleum Science & Engineering
_g70
942 _cARTICULO
100 1 _aMarins, L.P.M.
_942923
100 1 _aDuarte, D.G.
_942924
100 1 _aLoureiro, J.B.R.
_942925
100 1 _aMoraes, C.A.C.
_942926
999 _c171151