000 01489nab a2200205 4500
005 20260520000835.0
008 260224s2009 xxu
245 0 0 _aImportance of Initial momentum rate and air-fuel premixing on moderate or intense low oxigen dilution (MILD) combustion in a recuperative furnace
260 _a
_b
_cnov./dic. 2009
270 _a08/06/2010 ; 07/06/2010
300 _a7 p. ; 5349-5356
520 _aTranscripción del resumen del autor. This paper reports an investigation on the influences of air-fuel injection momentum rate and the air-fuel premixing on the moderate or intense low oxygen dilution (MILD) combustion in a 20-kW recuperative furnace. Various patterns of partially and fully premixed reactants have proven experimentally to work extremely well in the present furnace. H2 recorded for a variety of equivalence ratios at a firing rate of 10 kW. The present numerical study suggests that there is a critical momentum rate of the inlet fuel-air mixture below which the MILD combustion cannot occur. Also, it is revealed, both experimentally and numerically, that, above the critical rate, both the inlet fuel-air mixedness and momentum rate impose insignificant influence on the stability of and emissions from the MILD combustion.
581 _a6
773 0 _tEnergy & fuels
_g23
942 _cARTICULO
100 1 _aMi, Jianchum
_942223
100 1 _aLi, Pengfei
_942224
100 1 _aDally, Bassam B.
_942225
999 _c170763
_d170763