245 0 0 _aRapid detection and suppression of mining equipment cab fires
260 _a
_b
_cabr. 2010
270 _a10/05/2010 ; 10/05/2010
300 _a10 p. ; 425-435
520 _aThe National Institute for Occupational Safety and Health (NIOSH/PRL) conducted a series of large-scale experiments to evaluate the effectiveness of optical flame detectors, photoelectric smoke detectors, and combined ionization and photoelectric smoke detectors for rapidly detecting mining equipment cab fires. The detector alarm times were then used to trigger the discharge of a fire inerting system inside the cab to suppress cab material fires. This paper discusses the types of fire detectors tested, the experiments that were conducted, and the results that were obtained. Conclusions are that rapid detection of equipment cab fires can be achieved to trigger the discharge of a fire inerting system inside the cab to protect the operator in the cab.