000 01545nab a2200181 4500
005 20260520000833.0
008 260224s2010 xxu
245 0 0 _aFire resistance of steel C-joist floor assemblies
260 _a
_b
_cabr. 2010
270 _a05/05/2010 ; 05/05/2010
300 _a30 p. ; 375-405
520 _aThis paper discusses the factors that affect the fire resistance performance of lightweight steel-framed (LSF) unrestrained floor assemblies protected with Type X gypsum board ceiling finishes. Sixteen fire resistance experiments were conducted on full-scale load-bearing steel C-joist floor assemblies using the ULC standard fire exposure time–temperature curve that is similar to ASTM E119 standard. Parameters investigated in this study include the effects of insulation installation, insulation type, joist spacing, resilient channel installation, resilient channel spacing, type of sub-floor layer and number of sub-floor layers versus number of gypsum board layers. The impact of these parameters on the fire resistance of steel C-joist frame floor assemblies is discussed. The fire resistance of LSF floors appears to be essentially governed by the number of gypsum board layers, spacing of the joists or resilient channels where the gypsum boards are attached, sub-floor type and insulation type. Other parameters are of secondary importance.
581 _a2
773 0 _tFire Technology
_g46
942 _cARTICULO
100 1 _aSultan, Mohamed A.
_942114
999 _c170676
_d170676