000 01802nab a2200205 4500
005 20260520000817.0
008 260224s2009 xxu
245 0 0 _aRegeneration of silica gel using high-intensity ultrasonic under low temperatures
260 _a
_b
_cene. 2009
270 _a15/05/2009 ; 20/04/2009
300 _a6 p. ; 457-463
520 _aTranscripción del resúmen publicado por el autor: This paper presents the experimental study on the regeneration of silica gel using ultrasonics under low-temperature conditions. Four kinds of regeneration temperatures, including 35, 45, 55, and 65 °C, were chosen to investigate the new regeneration technology. The temperature and humidity of ambient air were kept at 24 ± 0.5 °C and 75 ± 5%, respectively, during the experiments. The ultrasonics used for this study was of 40 W in power and 25.6 kHz in frequency. The actual regeneration period for each experimental condition was set as 160 min, during which the weight decrement of silica gel was recorded every 8 min. The experimental results showed that ultrasonics could contribute to improving the regeneration efficiency of silica gel under low-temperature conditions. The role of ultrasonics in the regeneration appears to become more important under lower regeneration temperatures and a higher moisture ratio in silica gel. The study indicates that ultrasonics can help decrease the regeneration temperature of silica gel and, hence, bring about chances of energy conservation in industrial applications.
773 0 _tEnergy & fuels
_g23
942 _cARTICULO
100 1 _aYao, Ye
_940959
100 1 _aLiu, Shiqing
_940960
100 1 _aZhang, Weijiang
_940961
999 _c169606
_d169606
856 _uhttp://pubs.acs.org/doi/full/10.1021/ef8000554