_aLiquid levels and density _bCase histories with DP cell problems |
| 260 |
_aTexas _bThe Distillation Group _c2001 |
||
| 270 | _a2009-05-18 ; 12/01/2004 | ||
| 500 | _aPublicado en el sitio web de The Distillation Group(http://www.distillationgroup.com), donde pueden consultarse otros artículos sobre temas relacionados. ; Página visitada en enero de 2004. ; Navegadores de Internet | ||
| 520 | _aTranscripción del resumen presentado por el autor, en inglés Differential pressure (DP) cells are the most often used level measuring device in the process industries. Differential pressure cells measure the pressure difference between two points and send a differential pressure reading to the plant control system. Typically, DP cells are rated in inches of water equivalent. Standard ranges include 0 to 20, 0 to 50, 0 to 100, 0 to 200, and 0 to 500 inches of water differential pressure. The control system converts the DP cell reading into a liquid level based on an assumed specific gravity inside the vessel. Levels based on DP cells can err for different reasons. Previous columns have covered many reasons DP cells or sight glasses can give false readings. This column covers some case histories of specific DP cell problems | ||
| 942 | _cARCHIVO | ||
| 110 | 2 |
_aThe Distillation Group _926172 |
|
| 650 | 0 |
_aTratamiento de gas natural _9382 |
|
| 650 | 0 |
_aTratamiento de gases licuados _9381 |
|
| 650 | 0 |
_aFraccionamiento _97267 |
|
| 650 | 0 |
_aTorres de enfriamiento _96894 |
|
| 650 | 0 |
_aTorres fraccionadoras _999 |
|
| 650 | 0 |
_aProcesos criogénicos _93008 |
|
| 650 | 0 |
_aDeetanización _91262 |
|
| 650 | 0 |
_aRecuperación de gases licuados _96399 |
|
| 650 | 0 |
_aDiagrama de flujos _923701 |
|
| 650 | 0 |
_aCondiciones operativas _925313 |
|
| 710 | 2 |
_aThe Distillation Group _926172 |
|
| 999 |
_c153589 _d153589 |
||
| 856 | _uhttp://www.distillationgroup.com/technical/p095.htm | ||