000 01646nmc a2200241 4500
005 20260520005822.0
008 260224s xxu
082 _aCD I249 1 0013788
245 0 0 _aPreliminary earthquake response analysis of 200,000kl large capacity above-ground LNG storage tank for the basic design section
270 _a12/09/06 ; 22/07/2003
300 _a18 p.
500 _aDisponible en CD en formato PDF
520 _aTranscripción del abstract original del autor: In this study, preliminary earthquake response analysis of 200,000kl large capacity aboveground LNG storage tank for the basic design section under development by DAEWOO E&C Co. LTD has been performed. In this study, more accurate seismic response analysis considering fluid-structure interaction by using a general-purpose finite element analysis program ANSYS has been performed. From the results, which comparable to the theoretical solutions, of modal analysis on inner liquid, it has been validated the modeling of LNG liquid by finite element. Base on these results, the modal analysis on fluid-structure interaction system of LNG storage tank also has been conducted. Finally the seismic analysis of 200,000kl large capacity LNG storage tank has been carried out in time domain.
773 _g
942 _cCONGTP
100 1 _aJin, Byeong-Moo
_922277
100 1 _aChung, Chul Hun
_922278
110 2 _aInternational Gas Union, IGU
_913105
111 2 _aWorld Gas Conference (22nd. : 2003 jun 1-5 : Tokyo)
_922029
700 1 _aChung, Chul Hun
_922278
710 2 _aInternational Gas Union, IGU
_913105
999 _c149657
_d149657