| 000 | 01578nmc a2200217 4500 | ||
|---|---|---|---|
| 005 | 20260520005819.0 | ||
| 008 | 260224s xxu | ||
| 082 | _aCD I249 1 0013788 | ||
| 245 | 0 | 0 |
_aLightweight high temperature test furnace _b21st century technology |
| 270 | _a12/09/06 ; 22/07/2003 | ||
| 300 | _a14 p. | ||
| 500 | _aDisponible en CD en formato PDF | ||
| 520 | _aTranscripción del abstract original del autor: New high-temperature lightweight furnace design offers potential energy savings, thus reducing emissions and costs, and improves product quality. Gasunie Research 12 m3 test furnace: ; 36% less heat needed to heat up the furnace ; first tests shown that 18% of flue gas heat loss saved through pulse/pause firing ; reduced carbon dioxide and gaseous hydrogen fluorides (HF) emissions ; improved temperature homogeneity in product batch enables higher throughput ; new dust-free combination of Refractory Ceramic Fibres (RCFs) have been tested successfully up to 1250 °C ; new high-temperature vitreous wool (RCFs) with high solubility in body fluids and hence no hazard classification has been successfully tested ; furnace control system developed and tested with good results, based on a standard industrial PLC, within stringent gas safety requirements. | ||
| 773 | _g | ||
| 942 | _cCONGTP | ||
| 100 | 1 |
_aGroot, F.C. de _922202 |
|
| 110 | 2 |
_aInternational Gas Union, IGU _913105 |
|
| 111 | 2 |
_aWorld Gas Conference (22nd. : 2003 jun 1-5 : Tokyo) _922029 |
|
| 710 | 2 |
_aInternational Gas Union, IGU _913105 |
|
| 999 |
_c149603 _d149603 |
||