Image from Google Jackets

Polyamide 6 and Polyurethane Used as Liner for Hydrogen Composite Cylinder An Estimation of Fire Behaviours

By: Language: Inglés Publication details: mar. 2016Description: 23 p. ; 397-420 In: Fire Technology 52Summary: Transcripción del resúmen realizada por el autor: The most advanced gas storage cylinders are composed of a high molecular weight polymeric liner and fibre reinforced composite. The goal of this paper is to study in ISO 5660 cone calorimeter the thermal behaviours of carbon fibre/epoxy composite covered by a liner made of polyamide 6 (PA6) or polyurethane (PU). Time-to-ignition, amount and rate of mass loss, heat release rate, total heat release rate and effective heat of combustion were measured and calculated at three irradiance levels (20, 40 and 60 kW m-2). The main exhaust gaseous species evolution as well as oxygen consumption were also quantified during the thermal decomposition process. The transient temperatures were measured at middle-thickness of composite layer and at composite/liner interface by using K-type thermocouples. Indeed, these technical data play a significant role to choose the adequate liner to be used for full-composite cylinder application. Results show that the liner type has no effect on flaming ignition of exposed composite as well as the temperature profiles within materials. Comparing to PA6, the PU liner presents a faster melting and decomposition rate (i.e. with a lower thermal resistance), a lower heat release rate levels and low major gas (i.e. CO, CO2 and NO) emission yields (i.e. a lower gaseous product toxicity). Based on the comparison of the fire-to-reaction properties, the PU thermoplastics are recommended to be used as liner to cover gas storage composite cylinder.
Item type: Artículo de Revista
Holdings
Current library Status Barcode
Biblioteca Alejandro Angel Bulgheroni Not for loan 200061906

Transcripción del resúmen realizada por el autor: The most advanced gas storage cylinders are composed of a high molecular weight polymeric liner and fibre reinforced composite. The goal of this paper is to study in ISO 5660 cone calorimeter the thermal behaviours of carbon fibre/epoxy composite covered by a liner made of polyamide 6 (PA6) or polyurethane (PU). Time-to-ignition, amount and rate of mass loss, heat release rate, total heat release rate and effective heat of combustion were measured and calculated at three irradiance levels (20, 40 and 60 kW m-2). The main exhaust gaseous species evolution as well as oxygen consumption were also quantified during the thermal decomposition process. The transient temperatures were measured at middle-thickness of composite layer and at composite/liner interface by using K-type thermocouples. Indeed, these technical data play a significant role to choose the adequate liner to be used for full-composite cylinder application. Results show that the liner type has no effect on flaming ignition of exposed composite as well as the temperature profiles within materials. Comparing to PA6, the PU liner presents a faster melting and decomposition rate (i.e. with a lower thermal resistance), a lower heat release rate levels and low major gas (i.e. CO, CO2 and NO) emission yields (i.e. a lower gaseous product toxicity). Based on the comparison of the fire-to-reaction properties, the PU thermoplastics are recommended to be used as liner to cover gas storage composite cylinder.

2



Instituto Argentino del Petróleo y del Gas
Maipú 639 (C1006ACG) – Buenos Aires – Argentina
Tel: (54 11) 5277 IAPG (4274)
Lu - Vie 11 a 17 hs
Mail: biblio@iapg.org.ar


Copyright © 2026, Instituto Argentino del Petróleo y del Gas, todos los derechos reservados.

Protección de datos personales