Gas-Well Liquid Loading Probed With Advanced Instrumentation

By: Language: Inglés Publication details: mar. 2012Description: 19 p. ; 251-270 In: SPE Journal 17Summary: Transcripción del resumen del autor Drop size, liquid holdup, and pressure drop have been measured simultaneously in real time. This experiment was carried out with air/water to establish annular two-phase flow on a 0.019-m-internal-diameter vertical pipe (7-m-long multiphase-flow facility). Drop concentration, distribution, and sizes in the core flow were measured using Spraytec, a light-diffraction-based instrumentation. Liquid holdup was logged with pairs of flush-mounted ring-conductance probes at various positions within the test section. Pressure drop was monitored using a differential-pressure meter mounted between two pressure taps separated by a distance of 1.5 m. Subtle changes were observed in the characteristic drop diameters around gas superficial velocities of 21 and 30 m/s following progressive, systematic increase in gas and liquid superficial velocities. The gas superficial velocities at which these changes were observed have been linked with transition boundaries to cocurrent and mist annular flows, respectively. Corresponding similar pseudochanges, finger-rinted in the liquid-holdup and pressure-drop data at these transition boundaries, in addition to film and drop-flow reversals captured on video, make the evidence more compelling. Applicability of core-flow dynamic data to explain various physical processes associated with gas-well liquid loading has been demonstrated.
Item type: Artículo de Revista
Holdings
Current library Status Barcode
Biblioteca Alejandro Angel Bulgheroni Not for loan 200059608

Transcripción del resumen del autor Drop size, liquid holdup, and pressure drop have been measured simultaneously in real time. This experiment was carried out with air/water to establish annular two-phase flow on a 0.019-m-internal-diameter vertical pipe (7-m-long multiphase-flow facility). Drop concentration, distribution, and sizes in the core flow were measured using Spraytec, a light-diffraction-based instrumentation. Liquid holdup was logged with pairs of flush-mounted ring-conductance probes at various positions within the test section. Pressure drop was monitored using a differential-pressure meter mounted between two pressure taps separated by a distance of 1.5 m. Subtle changes were observed in the characteristic drop diameters around gas superficial velocities of 21 and 30 m/s following progressive, systematic increase in gas and liquid superficial velocities. The gas superficial velocities at which these changes were observed have been linked with transition boundaries to cocurrent and mist annular flows, respectively. Corresponding similar pseudochanges, finger-rinted in the liquid-holdup and pressure-drop data at these transition boundaries, in addition to film and drop-flow reversals captured on video, make the evidence more compelling. Applicability of core-flow dynamic data to explain various physical processes associated with gas-well liquid loading has been demonstrated.

1



Instituto Argentino del Petróleo y del Gas
Maipú 639 (C1006ACG) – Buenos Aires – Argentina
Tel: (54 11) 5277 IAPG (4274)
Lu - Vie 11 a 17 hs
Mail: biblio@iapg.org.ar


Copyright © 2026, Instituto Argentino del Petróleo y del Gas, todos los derechos reservados.

Protección de datos personales