Image from Google Jackets

Experimental investigation of an office fire with a partially impaired sprinkler system

By: Publication details: jul. 2010Description: 31 p. ; 611-627 In: Fire Technology 46Summary: Transcripción del resumen del autor. In this work, an actual office fire with a partially impaired automatic sprinkler system was investigated. As per regulations, there were four sprinklers in this model office. In the research conducted here, the first three sprinklers were actuated without water supply, while the last sprinkler was supplied with water at the required operating pressure for a period of 30 min. The fire source, a burning plastic trash can filled with 0.5 kg of paper, burned the adjacent chair, desk, desktop computer, and then reached the interior wooden furniture. The results show that the single remaining sprinkler effectively controlled the fire spread for 30 min. The partially impaired sprinkler system does not completely extinguish the fire, but extends the available time for evacuation. Continuing the discharge from sprinklers is preferable since the heat release from the fire increased after water flow was terminated.
Item type: Artículo de Revista
Holdings
Current library Status Barcode
Biblioteca Alejandro Angel Bulgheroni Not for loan 200048250

Transcripción del resumen del autor. In this work, an actual office fire with a partially impaired automatic sprinkler system was investigated. As per regulations, there were four sprinklers in this model office. In the research conducted here, the first three sprinklers were actuated without water supply, while the last sprinkler was supplied with water at the required operating pressure for a period of 30 min. The fire source, a burning plastic trash can filled with 0.5 kg of paper, burned the adjacent chair, desk, desktop computer, and then reached the interior wooden furniture. The results show that the single remaining sprinkler effectively controlled the fire spread for 30 min. The partially impaired sprinkler system does not completely extinguish the fire, but extends the available time for evacuation. Continuing the discharge from sprinklers is preferable since the heat release from the fire increased after water flow was terminated.

3



Instituto Argentino del Petróleo y del Gas
Maipú 639 (C1006ACG) – Buenos Aires – Argentina
Tel: (54 11) 5277 IAPG (4274)
Lu - Vie 11 a 17 hs
Mail: biblio@iapg.org.ar


Copyright © 2026, Instituto Argentino del Petróleo y del Gas, todos los derechos reservados.

Protección de datos personales