Testing corrosion rates on steel piping in geothermal district heating
Publication details: mayo 2008Description: 4 p. ; 56-59 In: Materials Performance 47Summary: Transcripción del resumen del autor. The St-37 carbon steel piping in a geothermal heating system experienced increasing corrosion leaks. Tests with pipe steel coupons showed that while uniform corrosion rates were low, pitting rates were high. Sulfate-reducing bacteria were the main cause. Changes in fluid velocities and the addition of a bacteriacide were recommended.| Current library | Status | Barcode | |
|---|---|---|---|
| Biblioteca Alejandro Angel Bulgheroni | Not for loan | 200047776 |
Transcripción del resumen del autor. The St-37 carbon steel piping in a geothermal heating system experienced increasing corrosion leaks. Tests with pipe steel coupons showed that while uniform corrosion rates were low, pitting rates were high. Sulfate-reducing bacteria were the main cause. Changes in fluid velocities and the addition of a bacteriacide were recommended.