Image from Google Jackets

Metal corrosion rate determination of different solutions and reinforced concrete specimens by means of a noncontacting corrosion method

By: Publication details: mayo 2010Description: 10 p. ; 056001 In: Corrosion 66Summary: Transcripción del resumen del autor. All the current techniques used to measure the metallic corrosion require contact with the metal. Particularly, in the case of reinforcement corrosion, this signifies the need to reach the bar that is embedded in the concrete, which consequently may result in the disruption of the integrity of the real structures. This paper studies the limits of application of a new methodfor polarizing the reinforcement or any metal in an electrolyte, without the need of direct contact. The polarization is obtained through the induction of current from an external electrical field. The current runs through the electrolyte and the metal in parallel, depending on the electrode arrangement. The resulting polarization resistance calculated is termed as inductive, Rp = Rpi, as reported in a previous paper. The inductive Rp is calculated by the model of resistances in parallel, which requires a separate measurement of the electrolyte ohmic resistance. In this study, solutions with several resistivities and concrete specimens with and without chlorides have been tested. Results indicate that electrolytes of low resistivity mask the measurement, and consequently, Rpi could not be calculated. In electrolytes with high resistivity, such as concrete, the feasibility is found to depend on the relative values of Re and Rpi.
Item type: Artículo de Revista
Holdings
Current library Status Barcode
Biblioteca Alejandro Angel Bulgheroni Not for loan 200047329

Transcripción del resumen del autor. All the current techniques used to measure the metallic corrosion require contact with the metal. Particularly, in the case of reinforcement corrosion, this signifies the need to reach the bar that is embedded in the concrete, which consequently may result in the disruption of the integrity of the real structures. This paper studies the limits of application of a new methodfor polarizing the reinforcement or any metal in an electrolyte, without the need of direct contact. The polarization is obtained through the induction of current from an external electrical field. The current runs through the electrolyte and the metal in parallel, depending on the electrode arrangement. The resulting polarization resistance calculated is termed as inductive, Rp = Rpi, as reported in a previous paper. The inductive Rp is calculated by the model of resistances in parallel, which requires a separate measurement of the electrolyte ohmic resistance. In this study, solutions with several resistivities and concrete specimens with and without chlorides have been tested. Results indicate that electrolytes of low resistivity mask the measurement, and consequently, Rpi could not be calculated. In electrolytes with high resistivity, such as concrete, the feasibility is found to depend on the relative values of Re and Rpi.

5



Instituto Argentino del Petróleo y del Gas
Maipú 639 (C1006ACG) – Buenos Aires – Argentina
Tel: (54 11) 5277 IAPG (4274)
Lu - Vie 11 a 17 hs
Mail: biblio@iapg.org.ar


Copyright © 2026, Instituto Argentino del Petróleo y del Gas, todos los derechos reservados.

Protección de datos personales