Image from Google Jackets

On the end-effect correction for Couette type oil-field direct-indicating viscometers for Newtonian and non-Newtonian fluids

By: Publication details: mar. 2010Description: 10 p. ; 37-46 In: Journal of Petroleum Science & Engineering 71Summary: Transcripción del resumen del autor. Analysis and experimental results are presented which quantify the magnitude of end-effects for direct- indicating, narrow gap, rotating cylinder viscometers used extensively in oil- eld, for Newtonian and non- Newtonian uids. Such viscometers have already embedded at manufacturing stage an end-effect correction and give directly the shear stress which does not allow end-effect quanti cation in a straight forward manner. The presented analysis resolves this problem by estimating the embedded correction, which has been determined as 6.69% of the torque developed along the cylindrical part of the stationary bob of this viscometer. Experimental results with Newtonian and non-Newtonian uids show that there is no additional end-effect from the bottom of the stationary bob. However, there is additional end-effect contribution from the top section of the bob, which has not been taken into account in the design and manufacturing of the instrument. Its magnitude ranges from 5 to 6% for the Newtonian uid and the high shear rate range for the non- Newtonian uid, to 12% for the low shear rate range for the non-Newtonian uid tested, while the impact on drilling situations is also discussed.
Item type: Artículo de Revista
Holdings
Current library Status Barcode
Biblioteca Alejandro Angel Bulgheroni Not for loan 200046814

Transcripción del resumen del autor. Analysis and experimental results are presented which quantify the magnitude of end-effects for direct- indicating, narrow gap, rotating cylinder viscometers used extensively in oil- eld, for Newtonian and non- Newtonian uids. Such viscometers have already embedded at manufacturing stage an end-effect correction and give directly the shear stress which does not allow end-effect quanti cation in a straight forward manner. The presented analysis resolves this problem by estimating the embedded correction, which has been determined as 6.69% of the torque developed along the cylindrical part of the stationary bob of this viscometer. Experimental results with Newtonian and non-Newtonian uids show that there is no additional end-effect from the bottom of the stationary bob. However, there is additional end-effect contribution from the top section of the bob, which has not been taken into account in the design and manufacturing of the instrument. Its magnitude ranges from 5 to 6% for the Newtonian uid and the high shear rate range for the non- Newtonian uid, to 12% for the low shear rate range for the non-Newtonian uid tested, while the impact on drilling situations is also discussed.

1-2



Instituto Argentino del Petróleo y del Gas
Maipú 639 (C1006ACG) – Buenos Aires – Argentina
Tel: (54 11) 5277 IAPG (4274)
Lu - Vie 11 a 17 hs
Mail: biblio@iapg.org.ar


Copyright © 2026, Instituto Argentino del Petróleo y del Gas, todos los derechos reservados.

Protección de datos personales