<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>01447nab a2200205   4500</leader>
  <controlfield tag="005">20260520004607.0</controlfield>
  <controlfield tag="008">260224s2018    xxu                 ing  </controlfield>
  <datafield tag="041" ind1=" " ind2=" ">
    <subfield code="a">Ingl&#xE9;s</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
    <subfield code="a">Attenuation of Thermal Radiation Through Water Mist</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="a"></subfield>
    <subfield code="b"></subfield>
    <subfield code="c">mar. 2018</subfield>
  </datafield>
  <datafield tag="270" ind1=" " ind2=" ">
    <subfield code="a">09/10/2020 ; 09/10/2020</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">7 p. ; 18-24</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">This article focuses on the interaction of thermal radiation with water droplets and the creation of water mist for the purpose of evaluating the decrease of heat flux when positioning a water curtain of various parameters between a radiation source and a radiometer. The change of water curtain parameters, affecting the passing through of thermal radiation, was performed using five nozzles with a variable spray characteristics. For the respective nozzles the attenuation of thermal radiation was determined and the thermal radiation transmittance was calculated. Water mist was created using a high-pressure pump and nozzles with a different size of the orifice. The measurement of droplet size was performed using the time-shift technique. The Omegalux radiant panel was used as the radiation source and the Hukseflux SBG01 radiometer with a working range of 0&amp;#x96;5 kW.m-2 was used as the detector</subfield>
  </datafield>
  <datafield tag="581" ind1=" " ind2=" ">
    <subfield code="a">1</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
    <subfield code="t">Process safety progress</subfield>
    <subfield code="g"></subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="c">ARTICULO</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
    <subfield code="a">Balner, Dalibor</subfield>
    <subfield code="9">59741</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
    <subfield code="a">Barcova, Karla</subfield>
    <subfield code="9">59742</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="c">193597</subfield>
    <subfield code="d">193597</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="9">261316</subfield>
    <subfield code="a">BAAB</subfield>
    <subfield code="b">BAAB</subfield>
    <subfield code="d">2026-03-06</subfield>
    <subfield code="j">200065959</subfield>
    <subfield code="l">0</subfield>
    <subfield code="p">200065959</subfield>
    <subfield code="r">2026-03-06 00:38:34</subfield>
    <subfield code="w">2026-03-06</subfield>
    <subfield code="y">ARTICULO</subfield>
  </datafield>
</record>
