    <subfield code="a">Theoretical Flammability Diagram for Analyzing Mine Gases</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="a"></subfield>
    <subfield code="b"></subfield>
    <subfield code="c">mar. 2015</subfield>
  </datafield>
  <datafield tag="270" ind1=" " ind2=" ">
    <subfield code="a">19/11/2019 ; 19/11/2019</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">15 p. ; 271-286</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">Transcripci&#xF3;n del resumen del autor. Out of the thermal balance method, a method of presenting mine fire data is proposed in this work. By grouping fuels into a pseudo fuel, grouping nitrogen and oxygen into a pseudo air, and using carbon dioxide as the diluent, a diluted flammability diagram is reconstructed for this oxygen-modified environment. The flammability envelop is controlled by oxygen availability, while the operation point is controlled by fuel/diluent availability. The relative position between the envelop and the operation point shows the flammable state of this mixture. Coward&amp;#x92;s explosive triangle is also applied using the limiting oxygen concentration derived from the diagram. Both are most useful in guiding the suppression operation for an underground coal mine fire.</subfield>
  </datafield>
  <datafield tag="581" ind1=" " ind2=" ">
    <subfield code="a">2</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
    <subfield code="t">Fire Technology</subfield>
    <subfield code="g"></subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="c">ARTICULO</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
    <subfield code="a">Ma, Tingguang</subfield>
    <subfield code="9">33335</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
    <subfield code="a">Larra&#xF1;aga, Michael</subfield>
    <subfield code="9">55496</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="c">193229</subfield>
    <subfield code="d">193229</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="9">260948</subfield>
    <subfield code="a">BAAB</subfield>
    <subfield code="b">BAAB</subfield>
    <subfield code="d">2026-03-06</subfield>
    <subfield code="j">200065545</subfield>
    <subfield code="l">0</subfield>
    <subfield code="p">200065545</subfield>
    <subfield code="r">2026-03-06 00:37:58</subfield>
    <subfield code="w">2026-03-06</subfield>
    <subfield code="y">ARTICULO</subfield>
  </datafield>
</record>