<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>02494nmc a2200193   4500</leader>
  <controlfield tag="005">20260520010350.0</controlfield>
  <controlfield tag="008">260224s        xxu                      </controlfield>
  <datafield tag="082" ind1=" " ind2=" ">
    <subfield code="a">PD I116 4 0015588</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
    <subfield code="a">Margies, Stefan</subfield>
    <subfield code="9">56775</subfield>
  </datafield>
  <datafield tag="111" ind1="2" ind2=" ">
    <subfield code="a">Congreso de integridad en instalaciones en el upstream y downstream de petr&#xF3;leo y gas (3er. : 2017 30 mayo - 1 jun. : Buenos Aires)</subfield>
    <subfield code="9">56732</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
    <subfield code="a">MFL results like a Laser Scan - taking analysis of complex corrosion and pinholes to the next level</subfield>
  </datafield>
  <datafield tag="270" ind1=" " ind2=" ">
    <subfield code="a">5/6/2019 ; 28/06/2017</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">7 p.</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">The purpose of this paper is to present the new ultra high resolution technology. ROSEN's new premium service, RoCorr MFL-A Ultra, now makes it possible to not only detect even the smallest pipeline defects (as small as 1mm diam.), but also to define the exact structure of defect groups and complex corrosion. Just like an MRI (Magnetic Resonance Imaging) scanner provides lifelike images of the interior of the human body, RoCorr MFL-A Ultra produces lifelike images of a pipe wall's structure. To this end, RoCorr MFL-A Ultra uses the highly innovative Pipeline ImagingTM method, which uses ultra-high-resolution sensors to gather several terabytes of data. These large amounts of data are then processed by the automated data processing application, AutoDataTM. Thus, RoCorr MFL-A Ultra not only permits a realistic evaluation of a pipeline's current integrity status, but also ensures a higher repeatability of inspection results, leading to much more accurate integrity assessments. RoCorr MFL-A Ultra can be applied under the same operational conditions as other ROSEN MFL services. Furthermore, the unique dual-sensor design ensures a seamless transition between your current high-resolution MFL data and the new ultra-high-resolution data, especially for corrosion growth applications. Key client's benefits ; Lifelike Pipeline ImagingTM report software ; Precise AutoDataTM algorithms ; Conclusive integrity assessments The ultra resolution and the increased sizing accuracy of this new service will lead to a reduction in unnecessary field verifications/repairs and finally reduce operators' cost. This paper will show the working principles of the technology and the results of the first year commercial applications all over the world.</subfield>
  </datafield>
  <datafield tag="773" ind1=" " ind2=" ">
    <subfield code="g"></subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="c">CONGTP</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="c">190513</subfield>
    <subfield code="d">190513</subfield>
  </datafield>
  <datafield tag="856" ind1=" " ind2=" ">
    <subfield code="u">https://biblioteca.iapg.org.ar/ArchivosAdjuntos/CongresoDeIntegridadEnInstalaciones2017/964.pdf</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="9">258332</subfield>
    <subfield code="a">CBAAB</subfield>
    <subfield code="b">CBAAB</subfield>
    <subfield code="c">PD I116 4 0015588</subfield>
    <subfield code="d">2026-03-06</subfield>
    <subfield code="j">200062768</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">PD I116 4 0015588</subfield>
    <subfield code="p">200062768</subfield>
    <subfield code="r">2026-03-06 00:20:34</subfield>
    <subfield code="w">2026-03-06</subfield>
    <subfield code="y">ARCHIVO</subfield>
  </datafield>
</record>
