<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>01719nab a2200217   4500</leader>
  <controlfield tag="005">20260520001113.0</controlfield>
  <controlfield tag="008">260224s2016    xxu                 ing  </controlfield>
  <datafield tag="041" ind1=" " ind2=" ">
    <subfield code="a">Ingl&#xE9;s</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
    <subfield code="a">Computational Modeling and Validation of Aerosol Deposition in Ventilation Ducts</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="a"></subfield>
    <subfield code="b"></subfield>
    <subfield code="c">ene. 2016</subfield>
  </datafield>
  <datafield tag="270" ind1=" " ind2=" ">
    <subfield code="a">25/07/2016 ; 25/07/2016</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">17 p. ; 149-166</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">Transcripci&#xF3;n del res&#xFA;men realizada por el autor: In fire models, the accurate prediction of aerosol and soot concentrations in the gas phase and their deposition thicknesses in the condensed phase is important for a wide range of applications, including human egress calculations, heat transfer in compartment fires, and forensic reconstructions. During a fire, in addition to soot transport by advection and diffusion, a significant amount of soot can be deposited on surfaces due to various mechanisms. As a first approach of quantifying aerosol deposition predictions under non-reacting flow conditions, this study identifies important parameters under various flow conditions and compares predicted aerosol deposition quantities to experimentally measured data. The computational tool used in this study was the computational fluid dynamics code, Fire Dynamics Simulator (FDS). Model predictions are compared to measured deposition velocities for various sizes of monodisperse fluorescent particles and various air velocities at the ceiling, wall, and floor of a ventilation duct.</subfield>
  </datafield>
  <datafield tag="581" ind1=" " ind2=" ">
    <subfield code="a">1</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
    <subfield code="t">Fire Technology</subfield>
    <subfield code="g">52</subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="c">ARTICULO</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
    <subfield code="a">Overholt, Kristopher J.</subfield>
    <subfield code="9">55461</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
    <subfield code="a">Floyd, Jason E.</subfield>
    <subfield code="9">55462</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
    <subfield code="a">Ezekoye, Ofodike A.</subfield>
    <subfield code="9">55463</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="c">189652</subfield>
    <subfield code="d">189652</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="9">257471</subfield>
    <subfield code="a">BAAB</subfield>
    <subfield code="b">BAAB</subfield>
    <subfield code="d">2026-03-06</subfield>
    <subfield code="j">200061892</subfield>
    <subfield code="l">0</subfield>
    <subfield code="p">200061892</subfield>
    <subfield code="r">2026-03-06 00:19:48</subfield>
    <subfield code="w">2026-03-06</subfield>
    <subfield code="y">ARTICULO</subfield>
  </datafield>
</record>
