<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>01596nab a2200217   4500</leader>
  <controlfield tag="005">20260520001110.0</controlfield>
  <controlfield tag="008">260224s2015    xxu                 ing  </controlfield>
  <datafield tag="041" ind1=" " ind2=" ">
    <subfield code="a">Ingl&#xE9;s</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
    <subfield code="a">Characteristics of Nuclear Facility Waste Bag Fires</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="a"></subfield>
    <subfield code="b"></subfield>
    <subfield code="c">ene. 2015</subfield>
  </datafield>
  <datafield tag="270" ind1=" " ind2=" ">
    <subfield code="a">11/09/2015 ; 11/09/2015</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">23 p. ; 129-152</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">Transcripci&#xF3;n del res&#xFA;men realizada por el autor: Waste bags from nuclear facilities filled with plastic personal protective equipment were tested to measure their fire hazard. Heat release rate (HRR), smoke yield and incident heat flux from waste bag fires were measured in a room/corner test apparatus. Three different size bags were tested in the corner of the room in order to check the effect of waste bag size. Full size waste bags were tested in the three different locations: in the center, in the corner and against the back wall of the room in order to check the effect of location. Bag fires can produce high HRRs (~800 kW) indicating that special caution is needed for waste bag management in nuclear facilities. Different size bags burn in a similar manner which allows a simple analytical tool to be developed to estimate transient HRR. In addition to the analytical tool, smoke yield and heat flux data can be used to simulate the waste bag fires and to validate fire model simulations.</subfield>
  </datafield>
  <datafield tag="581" ind1=" " ind2=" ">
    <subfield code="a">1</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
    <subfield code="t">Fire Technology</subfield>
    <subfield code="g">51</subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="c">ARTICULO</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
    <subfield code="a">You, Young-Geun</subfield>
    <subfield code="9">54768</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
    <subfield code="a">Park, Haejun</subfield>
    <subfield code="9">54769</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
    <subfield code="a">Dembsey, Nicholas A.</subfield>
    <subfield code="9">42110</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="c">189165</subfield>
    <subfield code="d">189165</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="9">256984</subfield>
    <subfield code="a">BAAB</subfield>
    <subfield code="b">BAAB</subfield>
    <subfield code="d">2026-03-06</subfield>
    <subfield code="j">200061397</subfield>
    <subfield code="l">0</subfield>
    <subfield code="p">200061397</subfield>
    <subfield code="r">2026-03-06 00:19:22</subfield>
    <subfield code="w">2026-03-06</subfield>
    <subfield code="y">ARTICULO</subfield>
  </datafield>
</record>
