<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>01526nab a2200193   4500</leader>
  <controlfield tag="005">20260520001029.0</controlfield>
  <controlfield tag="008">260224s2011    xxu                      </controlfield>
  <datafield tag="245" ind1="0" ind2="0">
    <subfield code="a">Implementation of acoustic emission source recognition for corrosion severity prediction</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="a"></subfield>
    <subfield code="b"></subfield>
    <subfield code="c">mayo 2011</subfield>
  </datafield>
  <datafield tag="270" ind1=" " ind2=" ">
    <subfield code="a">19/05/2011 ; 19/05/2011</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">11 p. ; 056001</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">Transcripci&#xF3;n del resumen del autor. Corrosion severity prediction is very useful information for maintenance planning. Acoustic emission (AE), a non-destructive testing method, can be applied to monitor corrosion severity. To improve its prediction reliability, a novel technique of applying acoustic source recognition is presented. In different acidic solutions and static corrosive potentials, stainless steel AISI 304 (UNS S30400) was used to study pitting corrosion, and carbon steel A36 (UNS K02600) was used to consider uniform corrosion. Consequently, each acoustic source was identified and used to predict the corrosion rate. In addition, the frequency spectrum and average frequency distribution of both corrosion types were studied. In conclusion, the frequency range can be used to classify types of corrosion. Either direct or indirect acoustic sources can be selected to monitor the corrosion severity. This method successfully increases the signal-to-noise ratio.</subfield>
  </datafield>
  <datafield tag="581" ind1=" " ind2=" ">
    <subfield code="a">5</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
    <subfield code="t">Corrosion</subfield>
    <subfield code="g">67</subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="c">ARTICULO</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
    <subfield code="a">Prateepasen, A.</subfield>
    <subfield code="9">49902</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
    <subfield code="a">Jirarungsatian, C.</subfield>
    <subfield code="9">49903</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="c">181830</subfield>
    <subfield code="d">181830</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="9">249649</subfield>
    <subfield code="a">BAAB</subfield>
    <subfield code="b">BAAB</subfield>
    <subfield code="d">2026-03-05</subfield>
    <subfield code="j">200053868</subfield>
    <subfield code="l">0</subfield>
    <subfield code="p">200053868</subfield>
    <subfield code="r">2026-03-05 23:51:59</subfield>
    <subfield code="w">2026-03-05</subfield>
    <subfield code="y">ARTICULO</subfield>
  </datafield>
</record>
