<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>02201nab a2200205   4500</leader>
  <controlfield tag="005">20260520004044.0</controlfield>
  <controlfield tag="008">260224s2010    xxu                      </controlfield>
  <datafield tag="245" ind1="0" ind2="0">
    <subfield code="a">Flammability characteristics of HFO-1234yf</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="a"></subfield>
    <subfield code="b"></subfield>
    <subfield code="c">jun. 2010</subfield>
  </datafield>
  <datafield tag="270" ind1=" " ind2=" ">
    <subfield code="a">18/08/2010 ; 18/08/2010</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">6 p. ; 150-155</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">Transcripci&#xF3;n del resumen del autor. A new low global warming refrigerant, CF3CF=CH2 (HFO-1234yf), has been developed to replace HFC-134a in automotive air conditioning systems. HFC-134a is being phased out in the European Union due to high global warming potential. HFO-1234yf is highly energy efficient, exhibits low toxicity, and can potentially be used in systems currently designed for refrigerant HFC-134a with minimal modifications. Significant work has been completed to assess the flammability characteristics of HFO-1234yf. Though it is flammable per ASTM E-681, it is significantly less so than HFC-152a which has also been considered as an HFC-134a alternative. HFO-1234yf has a relatively high lower flammability limit at 6.2 vol% in air. Computational Fluid Dynamics (CFD) modeling has shown it is very unlikely the lower flammability limit will be reached when the refrigerant is leaked into the passenger compartment of a vehicle. HFO-1234yf also has a high minimum ignition energy (MIE) from 5,000 to 10,000 mJ which indicates there may be very few potential ignition sources in a vehicle. It also has very low burning velocity at 1.5 cm/sec indicating low potential for damage should an ignition occur. Several automotive industry groups have completed extensive risk assessments which have concluded HFO-1234yf is safe to use as a refrigerant in vehicles. This article will review flammability test results and challenges that were overcome to measure flammability of a mildly flammable refrigerant as well as CFD modeling work for vehicle leakage scenarios. &#xA9; 2009 American Institute of Chemical Engineers Process Saf Prog, 2010</subfield>
  </datafield>
  <datafield tag="581" ind1=" " ind2=" ">
    <subfield code="a">2</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
    <subfield code="t">Process safety progress</subfield>
    <subfield code="g">29</subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="c">ARTICULO</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
    <subfield code="a">Minor, Barbara H.</subfield>
    <subfield code="9">46532</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
    <subfield code="a">Herrmann, David</subfield>
    <subfield code="9">46533</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
    <subfield code="a">Gravell, Robert</subfield>
    <subfield code="9">46534</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="c">176151</subfield>
    <subfield code="d">176151</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="9">243970</subfield>
    <subfield code="a">BAAB</subfield>
    <subfield code="b">BAAB</subfield>
    <subfield code="d">2026-03-05</subfield>
    <subfield code="j">200048074</subfield>
    <subfield code="l">0</subfield>
    <subfield code="p">200048074</subfield>
    <subfield code="r">2026-03-05 18:56:49</subfield>
    <subfield code="w">2026-03-05</subfield>
    <subfield code="y">ARTICULO</subfield>
  </datafield>
</record>
