<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>01690nab a2200205   4500</leader>
  <controlfield tag="005">20260520000923.0</controlfield>
  <controlfield tag="008">260224s2011    xxu                      </controlfield>
  <datafield tag="245" ind1="0" ind2="0">
    <subfield code="a">Active protection of fiber-reinforced polymer-wrapped reinforced concrete structures against corrosion</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="a"></subfield>
    <subfield code="b"></subfield>
    <subfield code="c">feb. 2011</subfield>
  </datafield>
  <datafield tag="270" ind1=" " ind2=" ">
    <subfield code="a">22/02/2011 ; 22/02/2011</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">11 p. ; 025002</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">Transcripci&#xF3;n del resumen del autor. Large numbers of reinforced concrete (RC) structures that have been damaged from corrosion of steel reinforcements are rehabilitated with fiber-reinforced polymer (FRP) composites. This paper investigates active protection of the steel embedded in concrete that is treated with surface-bonded carbon FRP. The electrically conductive carbon fiber is used as an anode while the reinforcing bar is used as a cathode. Concrete cylinder specimens with embedded steel bars are immersed in salt water, and anodic current is passed through the reinforcement to initiate cracking in concrete as a result of accelerated corrosion of steel. Carbon FRP sheets have been bonded adhesively to the cylinders. The adhesive has been modified to impart electrical conductivity. Specimens were exposed to a highly corrosive environment for a specified time. Pullout strength, mass loss, potentiodynamic scans, and the half-cell potential of steel are reported as metrics of performance of the samples. The proposed technique has been very effective in retarding the corrosion of steel.</subfield>
  </datafield>
  <datafield tag="581" ind1=" " ind2=" ">
    <subfield code="a">2</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
    <subfield code="t">Corrosion</subfield>
    <subfield code="g">67</subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="c">ARTICULO</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
    <subfield code="a">Gadve, S.</subfield>
    <subfield code="9">44597</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
    <subfield code="a">Mukherjee, A.</subfield>
    <subfield code="9">44598</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
    <subfield code="a">Malhotra, S.N.</subfield>
    <subfield code="9">44599</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="c">173473</subfield>
    <subfield code="d">173473</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="9">241292</subfield>
    <subfield code="a">BAAB</subfield>
    <subfield code="b">BAAB</subfield>
    <subfield code="d">2026-03-05</subfield>
    <subfield code="j">200051472</subfield>
    <subfield code="l">0</subfield>
    <subfield code="p">200051472</subfield>
    <subfield code="r">2026-03-05 16:09:41</subfield>
    <subfield code="w">2026-03-05</subfield>
    <subfield code="y">ARTICULO</subfield>
  </datafield>
</record>
