<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>01497nab a2200193   4500</leader>
  <controlfield tag="005">20260520002846.0</controlfield>
  <controlfield tag="008">260224s2010    xxu                      </controlfield>
  <datafield tag="245" ind1="0" ind2="0">
    <subfield code="a">Recovering energy at entry of natural gas into customer premises by employing a counter-flow vortex tube</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="a"></subfield>
    <subfield code="b"></subfield>
    <subfield code="c">nov./dic. 2010</subfield>
  </datafield>
  <datafield tag="270" ind1=" " ind2=" ">
    <subfield code="a">18/02/2011 ; 18/02/2011</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">10 p. ; 903-912</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">Transcripci&#xF3;n del resumen del autor. Throttling valves are currently utilised to reduce high-pressure natural gas flowing through the distribution pipeline to the working level of customers&amp;#x92; equipment. This wastes valuable energy of the gas. Due to low natural gas consumption at customer premises, it is not feasible to utilise expansion machines. In this study, a new idea is proposed to take advantage of the Vortex Tube and natural gas pressure reduction. The idea is to replace the throttling valve with a Vortex Tube in the natural gas pressure reduction system and take advantage of the generated cooling capacity. An experimental investigation was made to determine the effects of the cold orifice diameter and the energy separation of the counter-flow Vortex Tube when air and natural gas are used as the fluid. The energy separation was investigated by use of the experimentally obtained data.</subfield>
  </datafield>
  <datafield tag="581" ind1=" " ind2=" ">
    <subfield code="a">6</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
    <subfield code="t">Oil and Gas Science and Technology</subfield>
    <subfield code="g">65</subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="c">ARTICULO</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
    <subfield code="a">Farzaneh-Gord, M.</subfield>
    <subfield code="9">44565</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
    <subfield code="a">Kargaran, M.</subfield>
    <subfield code="9">44566</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="c">173385</subfield>
    <subfield code="d">173385</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="9">241204</subfield>
    <subfield code="a">BAAB</subfield>
    <subfield code="b">BAAB</subfield>
    <subfield code="d">2026-03-05</subfield>
    <subfield code="j">200051375</subfield>
    <subfield code="l">0</subfield>
    <subfield code="p">200051375</subfield>
    <subfield code="r">2026-03-05 16:09:18</subfield>
    <subfield code="w">2026-03-05</subfield>
    <subfield code="y">ARTICULO</subfield>
  </datafield>
</record>
