<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>01352nab a2200193   4500</leader>
  <controlfield tag="005">20260522171448.0</controlfield>
  <controlfield tag="008">260224s2009    xxu                      </controlfield>
  <datafield tag="100" ind1="1" ind2=" ">
    <subfield code="a">Duchateau, Christophe</subfield>
    <subfield code="9">41648</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
    <subfield code="a">Peytavy, Jean-Louis</subfield>
    <subfield code="9">28927</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
    <subfield code="a">Gl&#xE9;nat, Philippe</subfield>
    <subfield code="9">41649</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
    <subfield code="a">Laboratory evaluation of kinetic hydrate inhibitors</subfield>
    <subfield code="b">A procedure for enhancing the repeatability of test results</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="c">ene. 2009</subfield>
  </datafield>
  <datafield tag="270" ind1=" " ind2=" ">
    <subfield code="a">30/07/2009 ; 29/07/2009</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">4 p. ; 962-966</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">Transcripci&#xF3;n del res&#xFA;men publicado por el autor: Evaluation of kinetic hydrate inhibitors (KHIs) in laboratory high-pressure cells generally yields scattered results. In this work we propose a procedure that consists of characterizing the effectiveness of KHI on second hydrate formation. This procedure limits the stochastic character of hydrate crystallization using the persistence of precursory hydrate structures in water that has previously experienced hydrate formation and decomposition. It is shown that the presence of these precursors strongly increases the repeatability of results compared with systems containing "fresh water" and allows unambiguous discrimination between blank (uninhibited system) and KHI tests.</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
    <subfield code="t">Energy &amp; fuels</subfield>
    <subfield code="g">23</subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="c">ARTICULO</subfield>
    <subfield code="2">ddc</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="c">170223</subfield>
    <subfield code="d">170223</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="9">238042</subfield>
    <subfield code="a">BAAB</subfield>
    <subfield code="b">BAAB</subfield>
    <subfield code="d">2026-03-05</subfield>
    <subfield code="j">200045050</subfield>
    <subfield code="l">0</subfield>
    <subfield code="p">200045050</subfield>
    <subfield code="r">2026-03-05 15:12:29</subfield>
    <subfield code="w">2026-03-05</subfield>
    <subfield code="y">ARTICULO</subfield>
  </datafield>
</record>
