<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>01372nab a2200205   4500</leader>
  <controlfield tag="005">20260520000801.0</controlfield>
  <controlfield tag="008">260224s2008    xxu                      </controlfield>
  <datafield tag="245" ind1="0" ind2="0">
    <subfield code="a">Get more from vertical thermosiphon reboilers</subfield>
    <subfield code="b">The effects of three different heat-transfer-enhancement devices are outlined here</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="a"></subfield>
    <subfield code="b"></subfield>
    <subfield code="c">nov. 2008</subfield>
  </datafield>
  <datafield tag="270" ind1=" " ind2=" ">
    <subfield code="a">21/01/2009 ; 21/01/2009</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">2 p. ; 52-54</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">Transcripci&#xF3;n del res&#xFA;men publicado por el autor: Improvements in performance can be achieved with the application of heat-transfer-enhancement devices &amp;#x97; such as wire matrix inserts, twisted-tape inserts and helically coiled inserts &amp;#x97; in the subcooled zone of a vertical thermosiphon reboiler. These enhancement devices reduce the required heat-transfer surface area, subcooled zone length and maximum temperature of the reboiler tube wall, while increasing the overall heat-transfer coefficient, subcooled-zone overall heat-transfer coefficient and average heat flux rate. All together, these benefits translate into a reduction in the size of the exchanger, the area of installation and the initial investment.</subfield>
  </datafield>
  <datafield tag="581" ind1=" " ind2=" ">
    <subfield code="a">12</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
    <subfield code="t">Chemical Engineering</subfield>
    <subfield code="g">115</subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="c">ARTICULO</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
    <subfield code="a">Zadakbar, Omid</subfield>
    <subfield code="9">40182</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
    <subfield code="a">Vatani, Ali</subfield>
    <subfield code="9">40183</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
    <subfield code="a">Karimpour, Kianoosh</subfield>
    <subfield code="9">40184</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="c">168897</subfield>
    <subfield code="d">168897</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="9">236716</subfield>
    <subfield code="a">BAAB</subfield>
    <subfield code="b">BAAB</subfield>
    <subfield code="d">2026-03-05</subfield>
    <subfield code="j">200043685</subfield>
    <subfield code="l">0</subfield>
    <subfield code="p">200043685</subfield>
    <subfield code="r">2026-03-05 15:11:07</subfield>
    <subfield code="w">2026-03-05</subfield>
    <subfield code="y">ARTICULO</subfield>
  </datafield>
</record>
