<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>02480nmc a2200253   4500</leader>
  <controlfield tag="005">20260608201323.0</controlfield>
  <controlfield tag="008">260224s2000    xxu                 ing  </controlfield>
  <datafield tag="041" ind1=" " ind2=" ">
    <subfield code="a">Ingl&#xE9;s</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
    <subfield code="a">Sloley, Andrew W.</subfield>
    <subfield code="9">14648</subfield>
  </datafield>
  <datafield tag="110" ind1="2" ind2=" ">
    <subfield code="a">The Distillation Group</subfield>
    <subfield code="9">26172</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
    <subfield code="a">Steady under pressure</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="a">Texas</subfield>
    <subfield code="b">The Distillation Group</subfield>
    <subfield code="c">2000</subfield>
  </datafield>
  <datafield tag="270" ind1=" " ind2=" ">
    <subfield code="a">2009-05-20 ; 13/01/2004</subfield>
  </datafield>
  <datafield tag="500" ind1=" " ind2=" ">
    <subfield code="a">Publicado en el sitio web de The Distillation Group(http://www.distillationgroup.com), donde pueden consultarse otros art&#xED;culos sobre temas relacionados. ; P&#xE1;gina visitada en enero de 2004. ; Navegadores de Internet</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">Transcripci&#xF3;n del resumen presentado por el autor, en ingl&#xE9;s Most distillation control systems, either conventional or advanced, assume that the column operates at a constant pressure. Maintaining constant operation supports stable operation and unit profits. Pressure fluctuations make control more difficult and reduce unit performance. Pressure variations swing column vapor loads and temperature profiles. Using temperature control as a substitute for composition control requires using pressure compensation to maintain desired compositions. Varying pressure changes relative volatilities and affects fractionation performance. Vacuum columns are especially susceptible to this problem. Other, less commonly expected problems, can arise from pressure fluctuations. Pressure drops may also result in a normally single-phase feed to turn into a flashing feed. Having two-phase feed when expecting single phase feed can flood a column . Effective pressure control prevents column flooding and minimizes compensation requirements for temperature substitution in composition control. Effective pressure control improves advanced control and unit optimization by making running close to the unit's maximum capacity more reliable. While important, few sources have thoroughly examined distillation pressure control systems. The paper major process factors involved in selecting pressure control schemes and examines the major types of column pressure control, their characteristics, and application.</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Destilaci&#xF3;n</subfield>
    <subfield code="9">296</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Columnas de destilaci&#xF3;n</subfield>
    <subfield code="9">2630</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Condiciones operativas</subfield>
    <subfield code="9">25313</subfield>
  </datafield>
  <datafield tag="650" ind1=" " ind2="0">
    <subfield code="a">Medici&#xF3;n de presi&#xF3;n</subfield>
    <subfield code="9">69</subfield>
  </datafield>
  <datafield tag="710" ind1="2" ind2=" ">
    <subfield code="a">The Distillation Group</subfield>
    <subfield code="9">26172</subfield>
  </datafield>
  <datafield tag="856" ind1=" " ind2=" ">
    <subfield code="u">http://www.distillationgroup.com/technical/p081_01.htm</subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="c">ARCHIVO</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="c">153590</subfield>
    <subfield code="d">153590</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="9">221409</subfield>
    <subfield code="a">BVIAPG</subfield>
    <subfield code="b">BVIAPG</subfield>
    <subfield code="d">2026-03-05</subfield>
    <subfield code="j">200029739</subfield>
    <subfield code="l">0</subfield>
    <subfield code="p">200029739</subfield>
    <subfield code="r">2026-03-05 00:34:48</subfield>
    <subfield code="w">2026-03-05</subfield>
    <subfield code="y">INTERNET</subfield>
  </datafield>
</record>
