<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>01681nmc a2200229   4500</leader>
  <controlfield tag="005">20260520005828.0</controlfield>
  <controlfield tag="008">260224s        xxu                      </controlfield>
  <datafield tag="082" ind1=" " ind2=" ">
    <subfield code="a">CD I249 1 0013788</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
    <subfield code="a">Sakai, Ryo</subfield>
    <subfield code="9">22608</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
    <subfield code="a">Ishibashi, Koji</subfield>
    <subfield code="9">22609</subfield>
  </datafield>
  <datafield tag="110" ind1="2" ind2=" ">
    <subfield code="a">International Gas Union, IGU</subfield>
    <subfield code="9">13105</subfield>
  </datafield>
  <datafield tag="111" ind1="2" ind2=" ">
    <subfield code="a">World Gas Conference (22nd. : 2003 jun 1-5 : Tokyo)</subfield>
    <subfield code="9">22029</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
    <subfield code="a">Development of high-efficiency 50KW micro gas turbine cogeneration system</subfield>
  </datafield>
  <datafield tag="270" ind1=" " ind2=" ">
    <subfield code="a">12/09/06 ; 22/07/2003</subfield>
  </datafield>
  <datafield tag="300" ind1=" " ind2=" ">
    <subfield code="a">12 p.</subfield>
  </datafield>
  <datafield tag="500" ind1=" " ind2=" ">
    <subfield code="a">Disponible en CD en formato PDF</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">Transcripci&#xF3;n del abstract original del autor: Toho Gas Co., Ltd. evaluated performance and durability of the TPC-50R, the highly efficient regenerative-cycle micro gas turbine units developed by Toyota Turbine and Systems Inc., modified their operational issues, and expanded Toyota Turbine and systems' lineup since January 2002. This paper describes the design, development, specifications, evaluation, and operational experience of the TPC-50R. The TPC-50R has two types of equipment for the utilization of the heat recovered from exhaust gases. One is a heat source for hot water, and the other is for air conditioning. Toho Gas Co., Ltd. has evaluated both systems. The TPC-50R with a hot water heat recovery system was evaluated in its Technical Research Institute, where it achieved almost 6,000 hours. The TPC-50R with an absorption chiller / heater was also evaluated at Howa Sports Land, where it achieved approximately 5,000 hours.</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
    <subfield code="a">Ishibashi, Koji</subfield>
    <subfield code="9">22609</subfield>
  </datafield>
  <datafield tag="710" ind1="2" ind2=" ">
    <subfield code="a">International Gas Union, IGU</subfield>
    <subfield code="9">13105</subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="c">CONGTP</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="c">149981</subfield>
    <subfield code="d">149981</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="9">217800</subfield>
    <subfield code="a">BAAB</subfield>
    <subfield code="b">BAAB</subfield>
    <subfield code="c">CD I249 1 0013788</subfield>
    <subfield code="d">2026-03-04</subfield>
    <subfield code="j">200025987</subfield>
    <subfield code="l">0</subfield>
    <subfield code="o">CD I249 1 0013788</subfield>
    <subfield code="p">200025987</subfield>
    <subfield code="r">2026-03-04 16:39:10</subfield>
    <subfield code="w">2026-03-04</subfield>
    <subfield code="y">ARCHIVO</subfield>
  </datafield>
</record>
