<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>02254nmc a2200229   4500</leader>
  <controlfield tag="005">20260520005610.0</controlfield>
  <controlfield tag="008">260224s2001    xxu                 ing  </controlfield>
  <datafield tag="041" ind1=" " ind2=" ">
    <subfield code="a">Ingl&#xE9;s</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
    <subfield code="a">Log Normalization, a Very Important Task in the Petrophysical Evaluation for La Pe&#xF1;a and Tundy Fields</subfield>
    <subfield code="b">SPE 69607</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="a">Dallas, Texas</subfield>
    <subfield code="b">Society of Petroleum Engineers</subfield>
    <subfield code="c">2001</subfield>
  </datafield>
  <datafield tag="270" ind1=" " ind2=" ">
    <subfield code="a">12/09/06 ; 03/10/01</subfield>
  </datafield>
  <datafield tag="520" ind1=" " ind2=" ">
    <subfield code="a">The well logs available in the La Pe&#xF1;a and Tundy fields have been logged for different service companies from the 60&#x15B; (the oldest wells) up to the present time. The logging tool generations go from the oldest (Neutron in cps, Density gamma gamma, Microlog, Resistivity) to the modern technology (PI, CDL, CN, NMR, etc). This wide variety of logging tools technology made the normalization a critical step before getting into any Petrophysical Evaluation. Some logs corrections such as depth shift, wrong values corrections and eliminations, SP base line and others, were also applied before normalization. The main task of normalization was to obtain an homogeneous log data set because an important number of log traces showed signs of differing calibration and scaling. This became most apparent when the logs were displayed in cross sections and also when cross plots were compared with each other for different wells. This publication shows the importance, benefits and follows the log normalization procedure applied to 79 wells from La Pe&#xF1;a field and the 9 wells from Tundy field. Once log normalization was performed, the wireline log data base obtained was consistent and homogeneous which let us count with reliable results in the petrophysical evaluation.</subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="c">CONGTP</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
    <subfield code="a">Aguirre, Omar</subfield>
    <subfield code="9">5764</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
    <subfield code="a">Antelo, Roberto</subfield>
    <subfield code="9">5763</subfield>
  </datafield>
  <datafield tag="111" ind1="2" ind2=" ">
    <subfield code="a">Latin American and Caribbean Petroleum Engineering Conference (7th : 2001 mar. 25-28 : Buenos Aires, Argentina)</subfield>
    <subfield code="9">5738</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
    <subfield code="a">Antelo, Roberto</subfield>
    <subfield code="9">5763</subfield>
  </datafield>
  <datafield tag="711" ind1="2" ind2=" ">
    <subfield code="a">Latin American and Caribbean Petroleum Engineering Conference (7th : 2001 mar. 25-28 : Buenos Aires, Argentina)</subfield>
    <subfield code="9">5738</subfield>
  </datafield>
  <datafield tag="800" ind1="1" ind2=" ">
    <subfield code="a">Aguirre, Omar</subfield>
    <subfield code="9">5764</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="c">131169</subfield>
    <subfield code="d">131169</subfield>
  </datafield>
  <datafield tag="856" ind1=" " ind2=" ">
    <subfield code="u">https://biblioteca.iapg.org.ar/ArchivosAdjuntos/LACPEC2001/Spe69607.pdf</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="0">0</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="9">202091</subfield>
    <subfield code="a">BVIAPG</subfield>
    <subfield code="b">BVIAPG</subfield>
    <subfield code="d">2026-03-03</subfield>
    <subfield code="j">200003247</subfield>
    <subfield code="l">0</subfield>
    <subfield code="p">200003247</subfield>
    <subfield code="r">2026-03-03 01:41:18</subfield>
    <subfield code="w">2026-03-03</subfield>
    <subfield code="y">ARCHIVO</subfield>
  </datafield>
</record>
