Refractometric Sensing of Heavy Oils in Fluorescent Core Microcapillaries

By: Language: Inglés Publication details: mayo/jun. 2015Description: 8 p. ; 487-495 In: Oil and Gas Science and Technology 70Summary: Transcripción del resumen del autor: The refractometric sensing of calibrated heavy oils (density > 1 000 kg/m3) is demonstrated using fluorescent-core microcapillaries. A 25-micron capillary channel was first coated with a high-index layer of fluorescent silicon Quantum Dots (QD). This QD film supports the development of cylindrical Whispering Gallery Mode (WGM) resonances inside the capillary. Heavy oils spanning a wide range of refractive index were pumped into the capillary channel, causing large shifts in the fluorescence WGM resonant wavelengths. The sensitivity for heavy oils approached 250 nm per Refractive Index Unit (nm/RIU) at the higher oil indices, which is the highest sensitivity so far observed for a refractometric sensor operating in the fluorescence mode. This suggests that fluorescent core microcapillaries may be a viable microfluidic alternative for refractometric or chemical sensing in various stages of oil and gas processing, monitoring and usage.
Item type: Artículo de Revista
Holdings
Current library Status Barcode
Biblioteca Alejandro Angel Bulgheroni Not for loan 200061446

Transcripción del resumen del autor: The refractometric sensing of calibrated heavy oils (density > 1 000 kg/m3) is demonstrated using fluorescent-core microcapillaries. A 25-micron capillary channel was first coated with a high-index layer of fluorescent silicon Quantum Dots (QD). This QD film supports the development of cylindrical Whispering Gallery Mode (WGM) resonances inside the capillary. Heavy oils spanning a wide range of refractive index were pumped into the capillary channel, causing large shifts in the fluorescence WGM resonant wavelengths. The sensitivity for heavy oils approached 250 nm per Refractive Index Unit (nm/RIU) at the higher oil indices, which is the highest sensitivity so far observed for a refractometric sensor operating in the fluorescence mode. This suggests that fluorescent core microcapillaries may be a viable microfluidic alternative for refractometric or chemical sensing in various stages of oil and gas processing, monitoring and usage.

3



Instituto Argentino del Petróleo y del Gas
Maipú 639 (C1006ACG) – Buenos Aires – Argentina
Tel: (54 11) 5277 IAPG (4274)
Lu - Vie 11 a 17 hs
Mail: biblio@iapg.org.ar


Copyright © 2026, Instituto Argentino del Petróleo y del Gas, todos los derechos reservados.

Protección de datos personales