Pump intake pressure determined from fluid levels, dynamometers, and valve-test measurements

By: Publication details: abr. 2011Description: 8 p. ; 59-66 In: Journal of Canadian Petroleum Technology 50Summary: Transcripción del resumen del autor. Three pump-intake-pressure (PIP) calculation methods available for wells artificially lifted with sucker rods are discussed in detail in this paper. The values of PIP obtained from acoustic fluid-level measurements in wells with moderate pump submergence can yield PIP estimates that agree with those of pump fluid-load analysis. If PIPs determined using these methods do not agree, then the operator must review the data quality and may reduce the deviation by adjusting certain parameters affecting the calculations. Field data for a significant group of wells are used to compare the PIP results of the three methods. The results show that the PIP computed using the maximum and minimum pump dynamometer loads usually calculates a PIP that is too low, while the PIPs computed using the valve test loads are usually too high. Recommendations are presented for quality control of the computed values.
Item type: Artículo de Revista
Holdings
Current library Status Barcode
Biblioteca Alejandro Angel Bulgheroni Not for loan 200057523

Transcripción del resumen del autor. Three pump-intake-pressure (PIP) calculation methods available for wells artificially lifted with sucker rods are discussed in detail in this paper. The values of PIP obtained from acoustic fluid-level measurements in wells with moderate pump submergence can yield PIP estimates that agree with those of pump fluid-load analysis. If PIPs determined using these methods do not agree, then the operator must review the data quality and may reduce the deviation by adjusting certain parameters affecting the calculations. Field data for a significant group of wells are used to compare the PIP results of the three methods. The results show that the PIP computed using the maximum and minimum pump dynamometer loads usually calculates a PIP that is too low, while the PIPs computed using the valve test loads are usually too high. Recommendations are presented for quality control of the computed values.

4



Instituto Argentino del Petróleo y del Gas
Maipú 639 (C1006ACG) – Buenos Aires – Argentina
Tel: (54 11) 5277 IAPG (4274)
Lu - Vie 11 a 17 hs
Mail: biblio@iapg.org.ar


Copyright © 2026, Instituto Argentino del Petróleo y del Gas, todos los derechos reservados.

Protección de datos personales