Abnormal ultrasonic data: Internal pit growth or measurement error?
Publication details: feb. 2008Description: 5 p. ; 58-62 In: Materials Performance 47Summary: Transcripción del resumen del autor. Internal pits are routinely monitored using a number of externally mounted nonintrusive probes, including ultrasonic thickness (UT) measurement. This article presents the analysis of the root cause of an abnormal signal in the UT measurement of a pipeline| Current library | Status | Barcode | |
|---|---|---|---|
| Biblioteca Alejandro Angel Bulgheroni | Not for loan | 200056782 |
Transcripción del resumen del autor. Internal pits are routinely monitored using a number of externally mounted nonintrusive probes, including ultrasonic thickness (UT) measurement. This article presents the analysis of the root cause of an abnormal signal in the UT measurement of a pipeline