Investigation of cathodic protection of steel tubular wharf piles after 11 years of operation

By: Publication details: abr. 2009Description: 4 p. ; 28-31 In: Materials Performance 48Summary: Transcripción del resumen del autor. The sacrificial anode protection system of the steel tubular piles of a 100.000-deadweight tonnage wharf has operated for 11 years. This article discusses the design and investigation results of the protection system after operating for this time period.
Item type: Artículo de Revista
Holdings
Current library Status Barcode
Biblioteca Alejandro Angel Bulgheroni Not for loan 200047788

Transcripción del resumen del autor. The sacrificial anode protection system of the steel tubular piles of a 100.000-deadweight tonnage wharf has operated for 11 years. This article discusses the design and investigation results of the protection system after operating for this time period.