Impressed current cathodic protection needs constant power Phorgotten phenomena

By: Publication details: mayo 2009Description: 2 p. ; 32-33 In: Materials Performance 48Summary: Transcripción del resumen del autor. Constant power is critical to ensuring the effectiveness of impressed current cathodic protection systems. This includes not only standard alternating current-direct current rectifiers, but for alternative power sources such as wind-driven generators and solar cells
Item type: Artículo de Revista
Holdings
Current library Status Barcode
Biblioteca Alejandro Angel Bulgheroni Not for loan 200047781

Transcripción del resumen del autor. Constant power is critical to ensuring the effectiveness of impressed current cathodic protection systems. This includes not only standard alternating current-direct current rectifiers, but for alternative power sources such as wind-driven generators and solar cells