Image from Google Jackets

Corrosion control of type 316L stainless steel in sulfamic acid cleaning solutions

By: Publication details: jul. 2009Description: 10 p. ; 491-500 In: Corrosion 65Summary: Transcripción del resumen del autor. An investigation was conducted to better understand the corrosion behavior of Type 316L (UNS S31603) stainless steel in sulfamic acid (NH2HSO3) cleaning solutions and the relative merits of traditional corrosion control strategies. Gravimetric and electrochemical measurements in deaerated and uninhibited 10 wt% NH2HSO3 at 65°C revealed that corrosion proceeds in an active state and involves hydrogen evolution as the dominant cathodic process. Effective corrosion control attained through passivity can be attained through either anodic polarization or the addition of a chemical passivator (dissolved oxygen in this case). Upgrading to the more corrosion-resistant Type 2205 duplex stainless steel (UNS S32205) was not considered reliable because this alloy exhibited borderline passivity. Electrochemical and x-ray photoelectron spectroscopy (XPS) surface microanalytical measurements revealed that the effective corrosion control attained through the addition of a commercial diethylthiourea-containing organic inhibitor was related to the manner in which the absorbed diethylthiourea inhibits the hydrogen evolution reaction kinetics.
Item type: Artículo de Revista
Holdings
Current library Status Barcode
Biblioteca Alejandro Angel Bulgheroni Not for loan 200047596

Transcripción del resumen del autor. An investigation was conducted to better understand the corrosion behavior of Type 316L (UNS S31603) stainless steel in sulfamic acid (NH2HSO3) cleaning solutions and the relative merits of traditional corrosion control strategies. Gravimetric and electrochemical measurements in deaerated and uninhibited 10 wt% NH2HSO3 at 65°C revealed that corrosion proceeds in an active state and involves hydrogen evolution as the dominant cathodic process. Effective corrosion control attained through passivity can be attained through either anodic polarization or the addition of a chemical passivator (dissolved oxygen in this case). Upgrading to the more corrosion-resistant Type 2205 duplex stainless steel (UNS S32205) was not considered reliable because this alloy exhibited borderline passivity. Electrochemical and x-ray photoelectron spectroscopy (XPS) surface microanalytical measurements revealed that the effective corrosion control attained through the addition of a commercial diethylthiourea-containing organic inhibitor was related to the manner in which the absorbed diethylthiourea inhibits the hydrogen evolution reaction kinetics.

7



Instituto Argentino del Petróleo y del Gas
Maipú 639 (C1006ACG) – Buenos Aires – Argentina
Tel: (54 11) 5277 IAPG (4274)
Lu - Vie 11 a 17 hs
Mail: biblio@iapg.org.ar


Copyright © 2026, Instituto Argentino del Petróleo y del Gas, todos los derechos reservados.

Protección de datos personales