Effect of Vertical Length on Corrosion of Steel in the Tidal Zone

By: Publication details: oct. 2009Description: 8 p. ; 695-702 In: Corrosion 65Summary: Transcripción del resumen del autor. The corrosion loss of mild steel in the marine tidal zone varies considerably with elevation relative to mean tide. Classical studies on steel piles and electrically isolated coupons show quite different vertical corrosion profiles. This usually is attributed to the effect of differential aeration. In many practical applications, steel structures may be confined to just part of the tidal zone or may extend only partly into either the atmospheric zone or the immersion zone. This paper presents mass-loss profiles for steel strips of different lengths (0.20, 0.50, 1.0, and 3 m) exposed at various elevations in the atmospheric, tidal, and immersion zones at Jervis Bay, Australia, where the tidal range is around 1.2 m. Relatively little difference in the corrosion profile was observed in the corrosion profiles for 100-mm-long coupons and for the shorter strips, mainly because each strip or coupon was confined to exposure only in a single zone. However, very high, localized corrosion was observed for a 1-m strip with the lower end extending just into the immersion zone. The 3-m-long strip and the individual coupons, all extending from the immersion zone to the atmospheric zone, displayed corrosion loss profiles generally consistent with those reported in classical studies.
Item type: Artículo de Revista
Holdings
Current library Status Barcode
Biblioteca Alejandro Angel Bulgheroni Not for loan 200046698

Transcripción del resumen del autor. The corrosion loss of mild steel in the marine tidal zone varies considerably with elevation relative to mean tide. Classical studies on steel piles and electrically isolated coupons show quite different vertical corrosion profiles. This usually is attributed to the effect of differential aeration. In many practical applications, steel structures may be confined to just part of the tidal zone or may extend only partly into either the atmospheric zone or the immersion zone. This paper presents mass-loss profiles for steel strips of different lengths (0.20, 0.50, 1.0, and 3 m) exposed at various elevations in the atmospheric, tidal, and immersion zones at Jervis Bay, Australia, where the tidal range is around 1.2 m. Relatively little difference in the corrosion profile was observed in the corrosion profiles for 100-mm-long coupons and for the shorter strips, mainly because each strip or coupon was confined to exposure only in a single zone. However, very high, localized corrosion was observed for a 1-m strip with the lower end extending just into the immersion zone. The 3-m-long strip and the individual coupons, all extending from the immersion zone to the atmospheric zone, displayed corrosion loss profiles generally consistent with those reported in classical studies.

10



Instituto Argentino del Petróleo y del Gas
Maipú 639 (C1006ACG) – Buenos Aires – Argentina
Tel: (54 11) 5277 IAPG (4274)
Lu - Vie 11 a 17 hs
Mail: biblio@iapg.org.ar


Copyright © 2026, Instituto Argentino del Petróleo y del Gas, todos los derechos reservados.

Protección de datos personales