Image from Google Jackets

Micromechanical adhesion force measurements between hydrate particles in hydrocarbon oils and their modifications

By: Publication details: nov./dic. 2009Description: 6 p. ; 5966-5971 In: Energy & fuels 23Summary: Transcripción del resumen del autor. Cyclopentane (CyC5) hydrate interparticle adhesion force measurements in the presence of small amounts of crude oil (up to 8 wt % in cyclopentane) were performed at 3.2 °C, under atmospheric pressure, using a micromechanical force apparatus. The adhesion forces obtained for cyclopentane hydrate in small amounts of crude oil in CyC5 bulk fluid were lower than those measured for CyC5 hydrate in pure CyC5 bulk fluid. CyC5 hydrate-normalized adhesive forces were measured to be on the order of 0.5 mN/m for samples containing approximately 5-8 wt % of Caratinga and Troika crude. Hydrate-normalized adhesive forces were found to increase when the surface-active components (including acids and asphaltenes) were removed from the crude oil. These results suggest that crude oils with high contents of acids and asphaltenes may be more likely to exhibit nonplugging tendencies in oil and gas flowlines.
Item type: Artículo de Revista
Holdings
Current library Status Barcode
Biblioteca Alejandro Angel Bulgheroni Not for loan 200045694

Transcripción del resumen del autor. Cyclopentane (CyC5) hydrate interparticle adhesion force measurements in the presence of small amounts of crude oil (up to 8 wt % in cyclopentane) were performed at 3.2 °C, under atmospheric pressure, using a micromechanical force apparatus. The adhesion forces obtained for cyclopentane hydrate in small amounts of crude oil in CyC5 bulk fluid were lower than those measured for CyC5 hydrate in pure CyC5 bulk fluid. CyC5 hydrate-normalized adhesive forces were measured to be on the order of 0.5 mN/m for samples containing approximately 5-8 wt % of Caratinga and Troika crude. Hydrate-normalized adhesive forces were found to increase when the surface-active components (including acids and asphaltenes) were removed from the crude oil. These results suggest that crude oils with high contents of acids and asphaltenes may be more likely to exhibit nonplugging tendencies in oil and gas flowlines.

6



Instituto Argentino del Petróleo y del Gas
Maipú 639 (C1006ACG) – Buenos Aires – Argentina
Tel: (54 11) 5277 IAPG (4274)
Lu - Vie 11 a 17 hs
Mail: biblio@iapg.org.ar


Copyright © 2026, Instituto Argentino del Petróleo y del Gas, todos los derechos reservados.

Protección de datos personales