Development of high-efficiency 50KW micro gas turbine cogeneration system

By: Contributor(s): Description: 12 pDDC classification:
  • CD I249 1 0013788
Summary: Transcripción del abstract original del autor: Toho Gas Co., Ltd. evaluated performance and durability of the TPC-50R, the highly efficient regenerative-cycle micro gas turbine units developed by Toyota Turbine and Systems Inc., modified their operational issues, and expanded Toyota Turbine and systems' lineup since January 2002. This paper describes the design, development, specifications, evaluation, and operational experience of the TPC-50R. The TPC-50R has two types of equipment for the utilization of the heat recovered from exhaust gases. One is a heat source for hot water, and the other is for air conditioning. Toho Gas Co., Ltd. has evaluated both systems. The TPC-50R with a hot water heat recovery system was evaluated in its Technical Research Institute, where it achieved almost 6,000 hours. The TPC-50R with an absorption chiller / heater was also evaluated at Howa Sports Land, where it achieved approximately 5,000 hours.
Item type: Congresos (trabajos presentados)
Holdings
Current library Call number Status Barcode
Biblioteca Alejandro Angel Bulgheroni CD I249 1 0013788 (Browse shelf(Opens below)) Not for loan 200025987

Disponible en CD en formato PDF

Transcripción del abstract original del autor: Toho Gas Co., Ltd. evaluated performance and durability of the TPC-50R, the highly efficient regenerative-cycle micro gas turbine units developed by Toyota Turbine and Systems Inc., modified their operational issues, and expanded Toyota Turbine and systems' lineup since January 2002. This paper describes the design, development, specifications, evaluation, and operational experience of the TPC-50R. The TPC-50R has two types of equipment for the utilization of the heat recovered from exhaust gases. One is a heat source for hot water, and the other is for air conditioning. Toho Gas Co., Ltd. has evaluated both systems. The TPC-50R with a hot water heat recovery system was evaluated in its Technical Research Institute, where it achieved almost 6,000 hours. The TPC-50R with an absorption chiller / heater was also evaluated at Howa Sports Land, where it achieved approximately 5,000 hours.



Instituto Argentino del Petróleo y del Gas
Maipú 639 (C1006ACG) – Buenos Aires – Argentina
Tel: (54 11) 5277 IAPG (4274)
Lu - Vie 11 a 17 hs
Mail: biblio@iapg.org.ar


Copyright © 2026, Instituto Argentino del Petróleo y del Gas, todos los derechos reservados.

Protección de datos personales