Image from Google Jackets

Condensation behaviour in natural gas experiences with PHLC-prediction in Europe

By: Contributor(s): Description: 11 pDDC classification:
  • CD I249 1 0013788
In: Summary: Transcripción del abstract original del autor: The model, which was developed by Delft University of Technology and Gastransport Services (the transportation company of the N.V. Nederlandse Gasunie) to predict the condensation behaviour of natural gas, has been extensively validated for the use with European natural gases. The European gases originated from various sources and are transported over long distances. The field test showed that the deviation between the measured and calculated PHLC-value is significantly higher for these European gases, compared to the results of three Dutch single source gases used during the initial model development. Most likely, these deviations result from the presence of heavy hydrocarbons not originating from the natural gas itself, the relatively large variations in the gas quality, and small discrepancies in the model. The large variations in gas quality and thus PHLC-values measured during the field test show that liquid drop out occurs under normal process conditions and that studies with respect to the condensation behaviour of natural gas are still an important topic for transport companies.
Item type: Congresos (trabajos presentados)
Holdings
Current library Call number Status Barcode
Biblioteca Alejandro Angel Bulgheroni CD I249 1 0013788 (Browse shelf(Opens below)) Not for loan 200025873

Disponible en CD en formato PDF

Transcripción del abstract original del autor: The model, which was developed by Delft University of Technology and Gastransport Services (the transportation company of the N.V. Nederlandse Gasunie) to predict the condensation behaviour of natural gas, has been extensively validated for the use with European natural gases. The European gases originated from various sources and are transported over long distances. The field test showed that the deviation between the measured and calculated PHLC-value is significantly higher for these European gases, compared to the results of three Dutch single source gases used during the initial model development. Most likely, these deviations result from the presence of heavy hydrocarbons not originating from the natural gas itself, the relatively large variations in the gas quality, and small discrepancies in the model. The large variations in gas quality and thus PHLC-values measured during the field test show that liquid drop out occurs under normal process conditions and that studies with respect to the condensation behaviour of natural gas are still an important topic for transport companies.



Instituto Argentino del Petróleo y del Gas
Maipú 639 (C1006ACG) – Buenos Aires – Argentina
Tel: (54 11) 5277 IAPG (4274)
Lu - Vie 11 a 17 hs
Mail: biblio@iapg.org.ar


Copyright © 2026, Instituto Argentino del Petróleo y del Gas, todos los derechos reservados.